Aeris H2 150 Plus
Supplier specifications and source limits, not an independent Hydrogenology test or a medical recommendation.
Model information
- Manufacturer/seller market
- Switzerland
- Manufacturing origin
- China, expressly stated by Emmewasser
- Technology
- SPE/PEM; platinum-coated titanium electrodes
- Required water
- Distilled or reverse-osmosis water
- Generation additives and consumables
- Ion-exchange resin filters; seller suggests replacement around 100 operating hours, optional with distilled water.
- H₂ generation / flow
- Up to 150 mL/min H₂
- Total generated output
- Up to 225 mL/min combined H₂/O₂
- Declared gas configuration
- Separate H₂ / optional combined mode
- Outlet claim (not inspired concentration)
- Not established
- Prepared-air concentration claim
- Not established
- Concentration limits
- Seller claims up to 99.9% hydrogen purity; not a fixed measured outlet value or inhaled concentration.
- Price context
- CHF 899 including Swiss VAT. Checkout calculates delivery; regional EU shipping/tax terms may differ. This is the Emmewasser direct-brand offer, not a financing instalment.
- Availability
- Not independently confirmed
- Source status
- Exact model verified in current official supplier documentation; specifications remain supplier claims.
- Last source check
- 2026-10-29
- Field-specific dates
- priceReview: 2026-11-02; price: 2026-11-02
- Notes and unresolved claims
- Separate H₂ and optional mixed-gas mode. Water-infusion accessory also advertised; one hardware record, not duplicated as another water model. OEM relationships to similar compact devices not confirmed.
Source links
- Official Swiss brand/seller exact-model technical table
- Price-only review — brand/manufacturer direct — 2 November 2026
The documentation level and original check dates above are retained. Listing a source does not mean every linked manual or report was read, nor that Hydrogenology verified supplier test claims.
Reader experiences
Only email-confirmed, moderator-approved ratings contribute. Email verification does not verify ownership or prove performance/safety. Comments may be submitted without a rating.
Rate or comment on this model
Request independent testing of this model
This uses the existing verified-request system. Exact aliases are reconciled with historical requests; one verified email counts once per model.
Before interpreting a specification
Source output, gas purity, mixed-gas composition and actual inspired exposure are different. Generator production of H₂ and O₂ alone does not establish their coadministration.