Languages

Read Hydrogenology in your language

Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Administration route

Hydrogen inhalation study library

Browse published research on inhaled molecular hydrogen, including studies in people, animals and laboratory models. Each record describes its methods, reported findings and limitations.

New to hydrogen inhalation? Read the evidence and safety guide

Choose an evidence group to browse its records. Start with the molecular hydrogen research overview.

Selected study comparison and interpretation notes
Inhaled hydrogen evidence guide

How to interpret molecular hydrogen inhalation research

The 234 records in this collection include 84 human and 150 preclinical studies involving inhaled molecular hydrogen. Exposure conditions differ across sources: H₂ concentration, gas mixture, flow, delivery system, session duration, treatment frequency and safety controls must all be examined separately.

Gas composition matters

H₂ delivered alone, diluted in air or supplied with oxygen describes different exposure conditions. Concentration and co-delivered gases should be reported explicitly.

Delivery and duration matter

Masks, cannulas, chambers and other systems may produce different exposure patterns. A short experimental session is not equivalent to repeated or prolonged use.

Safety context matters

Hydrogen is flammable. Engineering controls and validated equipment are separate from questions about biological or clinical outcomes.

What do human studies show?

Human inhalation research has produced positive, null and mixed findings. A change in a biomarker or brain-oxygenation measure is not the same as improved symptoms, function or survival. Gas mixtures, delivery systems and study populations differ; these studies cannot be combined into a single treatment effect.

Symptoms and clinical measures

A randomized COPD exacerbation trial found greater symptom-score improvement, while lung function and blood-gas outcomes did not differ significantly (PMID 33985501). The ulcerative-colitis pilot found no clear difference in clinical scores despite some endoscopic and microbiome signals (PMID 40868053). The hearing-loss trial reported a favorable change from baseline but no significant difference in absolute hearing threshold at three months (PMID 36507329). These results concern distinct conditions and endpoints.

Exercise and healthy physiology

Small crossover exercise studies reported selected secondary performance or biomarker differences. The running study's primary time-to-exhaustion outcome was null (PMID 31938004); the recovery study found differences in jumping and a relative urinary marker, with several other measures null (PMID 33380581). The uncontrolled brain-oxygenation pilot did not test cognitive benefit (PMID 41582106). In healthy women at rest, heart-rate variability was unchanged and oxygen saturation was slightly lower; the current check is limited to its abstract (PMID 41401441).

Observational findings and case reports

The hypertension cohort found an association with lower blood pressure after matching, but voluntary exposure and residual confounding prevent a causal conclusion (PMID 39600611). Four ME/CFS cases describe subjective improvement without a control group and with incomplete recovery; they cannot establish efficacy (PMID 37929512).

Safety is a separate question

Eight healthy adults in a monitored inpatient safety study had no clinically significant adverse events reported. The sample was too small to exclude uncommon harms and does not establish general device or home-use safety (PMID 34651133). No dose, device or personal use recommendation follows from this comparison.

Read the full safety context and sources.

What does the 4% figure mean?

About 4% hydrogen by volume in air is the commonly quoted lower flammability limit at room temperature and normal atmospheric pressure. Around this threshold, a hydrogen–air mixture can sustain a flame if ignited.

This is a fire-safety threshold, not a medically established safe inhalation limit. ‘Below 4%’ does not by itself mean that a device or treatment is safe. It is not a recommended dose or device setting.

Details and sources

The figure is an approximate boundary, not a safety margin. Flammability limits depend on temperature, pressure and the gas mixture. Equipment safety and effects on a person are separate questions.

Selection and verification method

Hydrogenology editorial, AI-assisted source comparison, 23 October 2026. This purposeful, non-exhaustive sample covers different designs, domains and result directions; it is not a systematic review, meta-analysis, formal risk-of-bias assessment or GRADE evaluation. Nine main full texts were compared with their records; PMID 41401441 was checked against its original abstract only. Supplementary files and registry histories were not fully rechecked. No independent clinician reviewer is claimed.

Each row links to the record and primary source. Participant recruitment and analysis denominators are kept separate; unknowns remain explicit. The complete collection and its pagination continue below.

On a narrow screen, scroll within the comparison table. Tab to the table region to use the arrow keys.

Ten selected human inhalation publications checked on 23 October 2026
Study / sourceDesign / participantsComparisonFindings, including null resultsLimits
Hydrogen inhalation is associated with a transient rightward shift in prefrontal oxyhemoglobin asymmetry and autonomic modulation

Scientific reports. 2026;16(1):6202. · PMID 41582106

Primary full text ↗
Exploratory single-arm physiological pilot; no sham or parallel control; not an RCT

15 recruited; 11 in TD-NIRS analysis after four quality-control exclusions; 9 in an influential-case sensitivity analysis.

Within-person baseline; no sham/control group.Oxyhemoglobin asymmetry shifted transiently rightward; the 9-person sensitivity comparison was not significant. Deoxyhemoglobin asymmetry and mean blood pressure showed no significant changes. Heart rate decreased. These physiological observations do not establish clinical benefit.Small uncontrolled study; influential cases, time/position effects and unknown inspired exposure limit inference. Y. Den represents the device manufacturer; CX Wellness supported the study.
Safety of prolonged inhalation of hydrogen gas in air in healthy adults

Critical Care Explorations. 2021;3(10):e0543. · PMID 34651133

Primary full text ↗
Prospective single-arm sequential-duration inpatient safety study

Eight participants completed exposure: n=2 for 24 hours, n=2 for 48 hours and n=4 for 72 hours; four were women and four men.

No concurrent control; participants had baseline testing and a four-hour 15 L/min medical-air period without H₂.All eight participants completed exposure without clinically significant adverse events. Neurological examination, pulmonary function and ECG showed no clinically significant deterioration. Small laboratory and heart-rate changes were considered clinically insignificant. This study assessed short-term monitored tolerability, not efficacy or general device safety.Eight healthy adults, one unblinded arm and short follow-up cannot exclude uncommon harms or establish safety in illness or unsupervised settings. Serum H₂ was not measured. Pappendick Family, Harvard Catalyst, NIH/NCATS and Harvard-affiliated institutions supported the work; authors disclosed no conflicts.
Hydrogen/oxygen therapy for the treatment of an acute exacerbation of chronic obstructive pulmonary disease: results of a multicenter, randomized, double-blind, parallel-group controlled trial

Respiratory Research. 2021;22:149. · PMID 33985501

Primary full text ↗
Ten-centre randomized double-blind active-controlled superiority trial

108 randomized, 54 per group; 107 in the full-analysis set and 93 in the per-protocol analysis.

A visually matched oxygen concentrator delivering 2 L/min air plus 1 L/min O₂; both groups received standard care.Day-7 BCSS symptom improvement favored hydrogen/oxygen (between-group difference −2.75 points, 95% CI −3.27 to −2.22); CAT scores also favored it. Lung function, arterial blood gases and oxygen saturation did not differ significantly. Adverse events occurred in 34/54 versus 42/54 participants; no deaths were reported.Seven-day symptom-focused trial; 108 randomized, 107 full-analysis and 93 per-protocol. Retrospective registration, exclusions and short follow-up limit interpretation; it does not establish long-term benefit or safety. No specific grant was reported; one author disclosed a journal associate-editor role. There was no heliox comparator.
Sixty-minute inhalation of molecular hydrogen decreases blood oxygen saturation but does not alter autonomic cardiac regulation at rest in healthy females

Can J Physiol Pharmacol. 2026;104:1–9. · PMID 41401441

Original abstract ↗
Randomized double-blind placebo-controlled crossover study

20 completed both sessions; number initially recruited not reported in the abstract.

Ambient air placebo, crossover.Mean oxygen saturation was lower with hydrogen (95.9% versus 96.7%; p≤0.007); authors considered the difference clinically insignificant. Heart-rate variability indices did not differ significantly (all p≥0.32). No clinical treatment benefit was tested.Abstract-only verification; small, short study of healthy young women. One author disclosed consultancy for H2 Global Group. Full methods, harms and recruitment flow remain unverified.
Impact of hydrogen-rich gas mixture inhalation through nasal cannula during post-exercise recovery period on subsequent oxidative stress, muscle damage, and exercise performances in men

Med Gas Res. 2020;10(4):155–162. · PMID 33380581

Primary full text ↗
Randomized double-blind placebo-controlled crossover repeated-measures study

8 participants

Ambient air delivered at the same total generator flow of 1,800 mL/min through a matched deviceThe relative rise in urinary 8-OHdG and decline in countermovement jump height were smaller with hydrogen-rich gas. Other exercise performance, blood oxidative-stress and muscle-damage markers did not differ significantly. Absolute urinary 8-OHdG did not differ between conditions at the same time point.Eight men, multiple outcomes and one post-recovery assessment; inspired gas fractions were estimated. Co-delivered oxygen prevents completely isolating hydrogen. Biomarker changes do not establish lasting recovery benefits. The disclosure names Helix Japan as funder and generator supplier, despite a separate financial-support entry stating none.
Short-term H_2 inhalation improves running performance and torso strength in healthy adults

Biology of sport. 2019;36(4):333-339. · PMID 31938004

Primary full text ↗
Randomized double-blind placebo-controlled crossover pilot

20 enrolled and completed the crossover study.

Room-air placebo, crossover.The primary running time-to-exhaustion outcome did not differ between conditions. Peak running velocity and preservation of torso strength favored hydrogen; handgrip, leg strength, bench-press endurance and maximal oxygen uptake did not. Selected inflammatory/hormonal markers changed. No adverse events were reported.Small short pilot with many secondary endpoints and limited diet/activity control; secondary signals do not override the null primary outcome. Serbian public and university bodies supported the study; authors declared no conflicts.
Hydrogen Gas Inhalation Improved Intestinal Microbiota in Ulcerative Colitis: A Randomised Double-Blind Placebo-Controlled Trial

Biomedicines. 2025;13(8):1799. · PMID 40868053

Primary full text ↗
Randomized double-blind placebo-controlled pilot trial

10 participants: H₂ n=5, placebo n=5

Air from a visually identical placebo machineMayo and clinical activity scores did not differ significantly between groups; remission was 3/5 versus 1/5 (p=0.24). A summed endoscopic score and microbiome beta-diversity showed differences, but alpha-diversity, blood tests and histological indices did not. No adverse events were observed. Recruitment stopped at ten after no clear clinical improvement.Exploratory pilot stopped early, five per arm; multiple endpoints, ongoing UC therapies and no long-term follow-up limit inference. MiZ supplied devices and supported the work; microbiome changes are not proof of symptom benefit.
Effectiveness and safety of hydrogen inhalation therapy as an additional treatment for hypertension in real-world practice: a retrospective, observational study in China

Frontiers in cardiovascular medicine. 2024;11:1391282. · PMID 39600611

Primary full text ↗
Retrospective observational two-cohort study with propensity-score matching; not randomized

4,126 eligible records; 2,364 in matched analysis, 1,182 per group. Missing-data sensitivity analyses are separate.

Matched routine-care cohort without hydrogen.At week 24, adjusted-by-matching cohort comparisons favored hydrogen for systolic (−7.81 mmHg, 95% CI −9.57 to −6.04) and diastolic pressure (−2.89 mmHg, 95% CI −4.24 to −1.54). Recorded adverse-event incidence did not differ significantly. This is an association, not randomized evidence of causation.Voluntary exposure, residual confounding, medication-dose changes and record-based harms ascertainment limit inference; adverse events may be undercounted. Authors reported no financial support and no commercial or financial conflicts.
Successful treatment of myalgic encephalomyelitis/chronic fatigue syndrome using hydrogen gas: four case reports

Medical Gas Research. 2024;14(2):84–86. · PMID 37929512

Primary full text ↗
Uncontrolled descriptive report of four cases

4 cases: two men and two women.

No control group; symptoms before treatment and during follow-up were compared within each case.Four cases described improvements in self-reported fatigue, pain, sleep or brain fog over differing follow-up periods. Recovery was incomplete: one participant still reported tiredness, and another experienced temporary symptom worsening. No randomized comparison or controlled estimate of treatment effect was available.Four self-assessed cases without control or blinding cannot separate treatment effects from fluctuation, expectation or concurrent factors. Four authors were MiZ employees; systematic harms assessment is not established.
A double-blinded, randomized controlled clinical trial of hydrogen inhalation therapy for idiopathic sudden sensorineural hearing loss

Frontiers in neuroscience. 2022;16:1024634. · PMID 36507329

Primary full text ↗
Multicentre double-blind randomized adjunct-treatment trial

82 randomized; 80 completed intervention (39 hydrogen, 41 control); 65 analyzed at three months (31 hydrogen, 34 control).

Air placebo plus the same background treatment; salvage steroid injections permitted.Three-month absolute hearing threshold did not differ significantly. Improvement from baseline favored hydrogen (32.7 versus 24.2 dB; p=0.048). No inhalation-related adverse effects were reported. Findings are mixed across the two primary measures.65 of 82 randomized participants analyzed, baseline treatment-delay imbalance, small sample and one-tailed efficacy tests; subgroup findings are exploratory. No speech-perception test. One author was employed by MiZ; the remaining authors declared no commercial or financial conflicts.
HumanInhaled H₂2026

A randomized controlled double-blind study on the brain protection of infantile patients with epileptic spasm syndrome through atomized inhalation of hydrogen-oxygen gas

Chen C, He W, Chen J, Shi XY, Yang G, Wang J, Wang YY, Hu PL, Han F, Meng Y, Zou LP. · Frontiers in Neurology. 2026;17:1781738.

Design
Single-center prospective randomized double-blind controlled trial
Sample
60 children were initially enrolled; seven discontinued for personal reasons or poor adherence, and 53 completed treatment and were included in the efficacy analysis: oxyhydrogen n=27 and medical-air control n=26.
Reported result

No significant between-group difference was found for spasm reduction (p=0.705), treatment response (p=0.950), EEG hypsarrhythmia disappearance (p=0.576), Kramer score (p=0.140), BASED score (p=0.168) or abnormal IL-6 rate (p=0.081). Overall adverse-reaction incidence was reported as comparable and no serious adverse events occurred, but elevated myocardial enzymes (28.3% vs 10.9%), gastrointestinal dysfunction (43.5% vs 23.9%) and abnormal liver function (8.7% vs 0%) were reported more often in the oxyhydrogen group, all p<0.05.

PreclinicalInhaled H₂2026

Association between hydrogen gas inhalation and cardiac output in an asphyxiated piglet model

Sakamoto K, Nakamura S, Tsuchiya T, Mitsuie T, Nakao Y, Htun Y, Yokota T, Inoue K, Inoue E, Wakabayashi T, Morimoto A, Koyano K, Konishi Y, Iwase T, Horii T, Kusaka T. · Scientific Reports. 2026;16:5262.

Design
Randomized two-group newborn-piglet hypoxic-ischemic resuscitation experiment
Sample
17 piglets randomized after resuscitation: hypoxic-ischemic control n=10 and H₂ inhalation n=7; cardiac-troponin analysis was available for 9 and 4 animals, respectively.
Reported result

Right-ventricular cardiac-output area under the curve and the five-hour value favored H₂; six-hour troponin T was lower in the small available subset. Left cardiac output, pulmonary-artery acceleration time, blood gases and several time-point comparisons did not differ significantly.

Mixed cell experiments and human case reportsInhaled H₂2026

Combined Molecular Hydrogen and Vitamin C Treatment in Irradiated Normal and Cancer Cell Models: An Exploratory In Vitro Study and Case Reports.

Miyakawa M, Zhang S, Behnan J, Zhang YI, Morganti C, Ito K, Isakson P, Uhlén P, Miyakawa A. · Medical Sciences. 2026;14:580.

Published full text reviewed

Design
Exploratory cell experiments plus two uncontrolled human case reports; not a randomized clinical trial.
Sample
Cell-viability replicate counts were 3, 3 and 4, respectively. Human cases were an 85-year-old man with stage IV salivary duct/parotid carcinoma and a 47-year-old woman with nasopharyngeal carcinoma. Imaging fields and cells are not independent patients.
Reported result

Combined 1 mM vitamin C and H₂ before and after irradiation produced 1.80-fold relative HUVEC viability (p < .05); most other HUVEC comparisons were not significant. In breast-cancer cells, corresponding relative viability was 0.63 before, 0.44 after and 0.44 before plus after irradiation, with increased caspase 3/7 activation. GL261 results depended on context; combined before-plus-after viability of 0.76 was not statistically significant, and the greatest reduction occurred without irradiation. DHE and selected EMT-related measurements trended downward, but many gene comparisons lacked significance markers. The two patient observations described improved or limited skin toxicity and pain without controls. No clinical tumor-control or survival effect was demonstrated.

PreclinicalInhaled H₂2026

Comparison of hydrogen administration methods in the treatment of radiation-induced heart disease in rats

Kura B, Pavelkova P, Kalocayova B, Sykora M, Vlkovicova J, Kluknavsky M, LeBaron T, Pobijakova M, Sagatova A, Slezak J. · Can J Physiol Pharmacol. 2026;104:1–13.

Design
Randomized controlled rat study
Sample
64 rats across eight groups and two experiment durations.
Reported result

Several injury and biomarker measures favored H₂, particularly inhalation, while many comparisons were null.

HumanInhaled H₂2026

Effect of hydrogen–oxygen inhalation on sleep disorders and abnormal mood: a single-blind, randomized controlled trial

Gao YH et al. · Med Gas Res. 2026;16(2):98–102.

Design
Single-blind randomized controlled trial
Sample
66 allocated: control n=25; H₂–O₂ n=41. Six Actiwatch datasets were lost; 60 were analyzed for objective sleep state.
Reported result

Objective total sleep time and wake time and the PSQI and depression scores favored the mixed gas. Between-group sleep efficiency after 7 days and anxiety did not significantly differ.

HumanInhaled H₂2026

Effects of Molecular Hydrogen Inhalation on Primary Dysmenorrhea: A Single-Group Time-Series Pilot Study

Yuko Yurugi; Iori Arisue; Carlos Egydio de Carvalho; Katsuya Watanabe; Masahito Watanabe · Japanese Journal of Complementary and Alternative Medicine. 2026;23(1):1-8.

Design
Uncontrolled single-group time-series pilot with three menstrual-cycle observations: before, during, and after hydrogen exposure. No randomization, no blinded placebo comparator.
Sample
13 enrolled and analyzed; no randomization or concurrent control group.
Reported result

Pain VAS (100 mm), mean ± SD: 66.5 ± 14.1 before, 34.6 ± 18.7 during and 57.7 ± 23.0 after the intervention cycle. Before versus during P < 0.001; during versus after P = 0.030; before versus after P = 0.230. These are within-person time comparisons, not a controlled treatment effect. Composite score medians were 4.0, 2.0 and 4.0; the source defines it as a sum despite a multiplication-style label.

PreclinicalInhaled H₂2026

Hydrogen alleviates sepsis-associated encephalopathy via ATG9B-dependent mitophagy

Yu X, Huang X, Song Y, Liu J, Huang F, Cui J, Xie K, Cui Y. · Molecular Medicine. 2026;32:173.

Published main text and supplements reviewed

Design
Cecal ligation and puncture (CLP) sepsis in young male mice, with air or hydrogen inhalation; complementary LPS-challenged HT22 neuronal cells, autophagy-inhibitor experiments and ATG9B knockdown in cells and hippocampus. Tissue ultrastructure was assessed blind to assignment; an overall random-allocation method and power calculation were not reported.
Sample
Male C57BL/6J mice aged 6–8 weeks, 20–25 g. Survival n = 20 per group; behavioral assays n = 10; many tissue assays n = 6; TEM n = 3 biologically independent mice per group. Cell assays generally n = 3 independent experiments. Total unique animals and allocation across the separate terminal, survival and behavioral experiments were not fully mapped; do not add technical fields or replicate counts as new animals.
Reported result

Authors report 7-day survival of 40% after CLP versus 75% with H₂ (20 mice per group; Kaplan–Meier/log-rank analysis). Cytokines TNF-alpha, IL-1beta and IL-6 were lower, with less histological neuronal injury and improved object-recognition and Y-maze measures. Exact graph-only effects were not independently digitized. Open-field total locomotor distance did not differ significantly across groups, including inhibitor and ATG9B-knockdown experiments. H₂ alone did not significantly change basal cytokines or the measured sham-group LDH, ALT and BNP values; this is not comprehensive proof of safety. In tissue and HT22 cells, H₂ was associated with ATG9B/PINK1/Parkin changes, lower p62 accumulation, increased LC3-related and mitochondria/lysosome colocalization, less ROS and apoptosis and better mitochondrial potential. 3-MA and ATG9B knockdown attenuated or abolished many of these responses, including behavioral and synaptic-marker differences in mice. Transcriptomic counts are internally inconsistent: the text states 3,735 changed genes while its 1,200 upregulated plus 886 downregulated genes sum to 2,086. Do not present the 3,735 total as independently verified. The pathway and colocalization experiments support a proposed mechanism, not proof of a universal H₂ sensor or human treatment effect.

PreclinicalInhaled H₂2026

Hydrogen Gas Therapy in Schizophrenia: Potential Neuroprotective Effects From an Animal Study

Miyake N, Haga T, Hirano SI, Ichikawa Y, Oguchi Y, Ando K. · Neuropsychopharmacology reports. 2026;46(2):e70117.

Design
Controlled preclinical study
Sample
Three groups. Methods report 7–10 mice per group, while the figure legend states 10–11; the exact allocation is inconsistently reported.
Reported result

Hydrogen was associated with higher brain hydroxyl radical antioxidant capacity. It did not significantly improve open-field behavior or prepulse inhibition; total antioxidant capacity also did not differ.

PreclinicalInhaled H₂2026

Hydrogen improves the efficacy of tetrandrine in the treatment of silicosis by inhibiting vascular endothelial mesenchymal transition caused by oxidative stress

Xiao K, Li M, Mu Y, Sun Y, Wang S, Chen S, Ma J, Cao M, Yang Y, Shao H, Ding X, Cui G, Du Z. · Frontiers in Bioengineering and Biotechnology. 2026;13:1668524.

Design
Randomized controlled mouse silicosis experiment with mechanistic assays and single-cell RNA sequencing
Sample
The H₂/tetrandrine experiment randomized 50 mice to five groups (n=10 each): control, silicosis, H₂, tetrandrine and H₂+tetrandrine. Most histology, imaging and molecular analyses used n=3 per group, hydroxyproline used n=4–6, and single-cell sequencing used one mouse per group.
Reported result

The Results section reports lung tetrandrine concentration of 38±6.1 ng/mg with tetrandrine alone and 73.4±11 ng/mg with H₂+tetrandrine; the abstract instead summarizes an increase from about 50 to 80 ng/mg. The combination group also showed lower histological injury/fibrosis and changes in oxidative-stress, apoptosis, EndMT and APP/CD74 measures versus the silicosis model, with several comparisons favoring combination over monotherapy.

HumanInhaled H₂2026

Hydrogen inhalation is associated with a transient rightward shift in prefrontal oxyhemoglobin asymmetry and autonomic modulation

Moriya M, Oyama K, Den Y, Yamada Y, Sakatani K. · Scientific reports. 2026;16(1):6202.

Design
Exploratory single-arm physiological pilot; no sham or parallel control; not an RCT
Sample
15 recruited; 11 in TD-NIRS analysis after four quality-control exclusions; 9 in an influential-case sensitivity analysis.
Reported result

Oxyhemoglobin asymmetry shifted transiently rightward; the 9-person sensitivity comparison was not significant. Deoxyhemoglobin asymmetry and mean blood pressure showed no significant changes. Heart rate decreased. These physiological observations do not establish clinical benefit.

HumanInhaled H₂2026

Long-term survival in patients with primary malignant brain tumors after postoperative home hydrogen inhalation: Three case reports

Xu KC, Kong XF, Qian W, Liang B, Li DG, Korpan NN. · World Journal of Clinical Cases. 2026;14(20):121466.

Design
Retrospective descriptive report of three uncontrolled cases
Sample
3 patients: two women aged 38 and 34 years and one man aged 56 years.
Reported result

The authors report no recurrence in cases 1 and 2, progressive radiological regression in case 3, and Karnofsky scores of 100, 100 and at least 80. These observations occurred after heterogeneous multimodal cancer treatment and cannot establish that hydrogen caused the outcomes.

HumanInhaled H₂2026

Metabolomic Alterations Associated with Adjunctive Hydrogen Gas Inhalation During Concurrent Chemoradiotherapy in Locally Advanced Head and Neck Cancer: A Pilot Study

Chitapanarux I, Autsavapromporn N, Onchan W, Chakrabandhu S, Muangwong P, Duangya A, Lertsiriladakul T, Panya A, Paemanee A. · Cancers (Basel). 2026;18(14):2191.

Design
Single-centre prospective assessor-blinded block-randomized two-arm pilot; no sham inhalation.
Sample
31 screened; 20 randomized (10 standard chemoradiotherapy, 10 chemoradiotherapy + hydrogen). Nineteen analyzed: 10 control and 9 hydrogen. One hydrogen participant withdrew consent at the 14th radiation fraction to seek herbal treatment.
Reported result

All between-group clinical comparisons in Table 2 were nonsignificant: chemotherapy delay 6/10 versus 3/9 (P = 0.25), median treatment duration 51.5 versus 48 days (P = 0.15), dermatitis P = 0.41, pharyngitis P = 0.31, mucositis P = 0.56, leucopenia P = 0.29, neutropenia P = 0.79 and thrombocytopenia P = 0.23. Direct change in uric-acid relative abundance was −39,917.15 ± 48,873.64 in controls versus −24,039.56 ± 13,924.30 with hydrogen (P = 0.11); these are relative-abundance units, not clinical serum concentrations. Separate within-group metabolite changes do not establish a hydrogen-specific effect. At February 2026 follow-up, 7/10 versus 8/9 had no disease, 2 versus 1 had local recurrence, and 1 versus 0 had disease-related death; these descriptive counts do not establish a survival or tumor-treatment effect.

PreclinicalInhaled H₂2026

Molecular Hydrogen Attenuates Chronic Inflammation and Delays the Onset of Ultraviolet B-Induced Skin Carcinogenesis in Mice

Hori F et al. · Int J Mol Sci. 2026;27(2):635.

Design
Two independently replicated controlled mouse UVB-carcinogenesis series
Sample
Two independent mouse series; the pathological table reports 14 control and 12 H₂-treated mice, while tissue comparisons commonly report n=4–7/group
Reported result

Papilloma onset was delayed and cumulative tumors were lower in both series. Survival and squamous-cell-carcinoma delay reached significance in only one series each; CPD levels were unchanged.

PreclinicalInhaled H₂2026

Molecular Hydrogen Modulates the Baroreflex Activity and Reduces the Vascular Adrenoreceptor Sensitivity to Phenylephrine and Lung Inflammation in Rats with Pulmonary Hypertension

Artemieva M, Kozaeva L, Kuropatkina T, Gufranov K, Atiakshin D, Medvedeva N, Medvedev O. · Biomedicines. 2026;14(3):494.

Design
Controlled rat pulmonary-hypertension study with separate ex-vivo aortic-ring experiments.
Sample
Inhalation experiment:31 rats in five groups (6,6,6,7,6). Separate vessel experiments report10 control and 10 monocrotaline rats; ring preparations are not additional animals.
Reported result

Hydrogen altered selected heart-rate/baroreflex responses and reduced phenylephrine-induced contraction in isolated aortic rings. It did not produce a sustained reduction in systemic blood pressure or improve right-ventricular pressure or hypertrophy. Lung microscopy suggested partial inflammatory changes, but total mast-cell counts were not significantly lower than the disease control; improved acetylcholine relaxation was also not statistically established.

HumanInhaled H₂2026

Molecular Hydrogen Reverses Sepsis-induced Immunoparalysis: Insights from Longitudinal Deep Immunophenotyping.

Wu CL, Lu JW, Ho YJ, Lui SW, Hsieh TY, Wang KY, Liu FC. · In Vivo. 2026;40(4):2554–2564.

Published full text reviewed

Design
Single uncontrolled longitudinal case report with clinical observations and flow cytometry.
Sample
One patient. Healthy reference observations were shown, but their sample size and detailed methods were not reported.
Reported result

Extubation was reported on 19 June, five days after hydrogen began, and subsequent radiographs improved. NT-proBNP had exceeded the assay ceiling of 35,000 pg/mL and later measured 12,597 pg/mL; the true initial value was unknown. Selected exhaustion markers and T- and B-cell subsets changed. Switched-memory B cells remained depleted, and transitional and regulatory B cells were absent or nearly absent. Candida parapsilosis fungemia complicated the course. Temporary stabilization did not translate into survival: the patient ultimately died.

PreclinicalInhaled H₂2026

Neuroprotective Effects of Molecular Hydrogen via Oxidative Stress and Neuroinflammation Regulation in a 5xFAD Mouse Model

Mo C, Bajgai J, Rahman MH, Ma H, Pham TT, Zhang H, Cao B, Jeong ES, Kim CS, Lee KJ. · Antioxidants (Basel, Switzerland). 2026;15(3):404.

Design
Randomized controlled experiment in transgenic Alzheimer-model and wild-type mice, using biochemical endpoints.
Sample
40 mice in four groups of ten, each with four males and six females. For Western blots, all ten hippocampal samples in a group were pooled into one sample and measured in three technical repeats; these are not ten independent protein measurements.
Reported result

Hydrogen reduced hippocampal ROS and amyloid-beta 42 and increased ATP, with improvements in some blood inflammatory and antioxidant markers. Amyloid-beta 40, blood-cell counts, serum nitric oxide, glutathione-peroxidase, IL-6 and GM-CSF did not significantly improve; the IL-13 change also was not significant. No learning, memory or functional behavior was tested. Protein-signalling conclusions are exploratory because the Western blots used pooled samples and technical repeats rather than independent animal measurements.

HumanInhaled H₂2026

Perioperative Hydrogen Inhalation and Postoperative Pain After Endoscopic Discectomy: A Pilot Non-Randomized Clinical Study with Exploratory Murine Data

Sung CH, Ko WC, Kung CC, Hung CF. · Medicina (Kaunas). 2026;62(9):1785. Published 16 September 2026.

Design
Pilot open-label, nonrandomized clinical study with sequential treatment periods; separate exploratory mouse and human blood-cell experiments in the same publication.
Sample
37 enrolled: 25 in the hydrogen period and 12 controls. Only 25 source-verifiable patients were analyzed (13 hydrogen, 12 control); original outcome records for 12 of 25 hydrogen-period participants were unavailable. No imputation.
Reported result

Pain, PACU: hydrogen: 2.04 ± 1.76; comparator: 5.25 ± 2.86; between group: Difference −3.21; 95% CI −5.02 to −1.41; Holm-adjusted p = 0.002. Pain, 1 hour: between group: Difference −2.42; 95% CI −3.85 to −0.98; Holm-adjusted p = 0.004. Pain, 6 / 12 / 24 hours: between group: Holm-adjusted p = 0.071 / 0.081 / 0.350; not significant. Pain, one month: between group: Difference −3.45; 95% CI −4.80 to −2.10; Holm-adjusted p < 0.001. Intraoperative fentanyl: hydrogen: 265.38 ± 99.24 micrograms; comparator: 347.92 ± 93.82 micrograms; between group: Difference −82.54 micrograms; 95% CI −162.61 to −2.47; p = 0.044. Rescue analgesia: hydrogen: 5/13; comparator: 10/12; between group: p = 0.041.

HumanInhaled H₂2026

Preliminary Effects of Hydrogen-Oxygen Inhalation on Nodule Size, IL-6, and Neutrophils in Patients with Small Pulmonary Nodules

Wei X, Zhang W, Li Y, Sha X, Yi H, Cui C. · Drug Design, Development and Therapy. 2026;20:605134. Published 8 July 2026.

Design
Single-centre randomized parallel clinical trial; random-number table and sealed envelopes; assessors, laboratory staff and statisticians blinded, patients/operators not blinded.
Sample
67 screened, 8 excluded before randomization; 59 randomized and analyzed (30 hydrogen–oxygen, 29 air). All randomized participants were reported to complete follow-up.
Reported result

Mean nodule diameter: hydrogen: 3.97 to 3.33 mm; reduction 0.64 mm, 95% CI 0.20 to 1.08; within-group p = 0.006; comparator: 4.29 to 4.19 mm; reduction 0.10 mm, 95% CI −0.32 to 0.52; within-group p = 0.641; Post-treatment diameter: 3.33 versus 4.19 mm; reported p < 0.001. The confidence intervals above describe changes within each group, not the difference between groups. IL-6: hydrogen: 5.04 to 3.68 pg/mL; comparator: 5.21 to 5.05 pg/mL; between group: Post-treatment p < 0.001. Neutrophils: hydrogen: 3.77 to 2.63 × 10^9/L; comparator: 4.10 to 3.85 × 10^9/L; between group: Post-treatment p = 0.001. CRP and Mayo malignancy risk score: between group: Post-treatment p = 0.239 and p = 0.946 respectively; not significant.

PreclinicalInhaled H₂2026

Preserved Acute Pulmonary Endothelial Homeostasis with Hydrogen Gas Inhalation After Neonatal Hypoxia-Ischemia Despite Increased Neutrophil Accumulation.

Yokota T, Iketani M, Tsuchiya T, Sakamoto K, Nakao Y, Mitsuie T, Inoue E, Inoue K, Kusaka T, Wakabayashi T, Koyano K, Miki T, Ueno M, Nakamura S, Kusaka T. · Biomedicines. 2026;14:1707.

Published full text reviewed

Design
Randomized two-group exploratory neonatal piglet experiment; blinded immunofluorescence field selection, without a formal power calculation.
Sample
16 piglets: 10 male and 6 female, weighing 1.5–2.1 kg; eight per group. Complete echocardiography was available for only five per group because it was added later in the protocol.
Reported result

There were no significant between-group differences in pH, PaO₂, PaCO₂, oxygen index or alveolar–arterial oxygen difference at the measured times. ICAM-1 (p = .40) and iNOS (p = .61) did not differ significantly. Lung neutrophil counts were higher with hydrogen (p < .05; 95% CI 8.6–171.9). In the smaller echocardiography subset, right cardiac output at five hours was 1,148 (157) versus 691 (173) mL/min, mean (SD), p < .05; its association with neutrophils had R² = .73, p < .01, in 10 animals. Left cardiac output did not differ significantly.

PreclinicalInhaled H₂2026

Protective Effects of Molecular Hydrogen on Noise-Induced Auditory and Cognitive Dysfunction

Lei Shi, Cong Wei, Bo Wang, Ning Yu, ShiMing Yang · Noise & Health. 2026;28(133):959–971.

Design
Controlled mouse experiment with reported random allocation.
Sample
72 mice: 20 unexposed controls, 26 noise only and 26 hydrogen–oxygen plus noise. Auditory and behavioral tests generally used 6 mice per group.
Reported result

Early hearing thresholds and some later inner-ear measures favored the gas group. Avoidance-task performance improved on some days but remained far below unexposed controls. Wave-I latency and the 70 dB startle prepulse comparison showed no significant improvement. Protein differences suggest possible pathways without demonstrating how protection occurred.

Computational studyInhaled H₂2026

Respiratory-physiology modeling of therapeutic hydrogen inhalation: defining the fraction of inspired hydrogen (FiH2) and flow-rate requirements.

LeBaron TW, Ohno K, Salomez-Ihl C, Cinquin P, Boucher F, Sano M, Kheir JN. · Respiratory Research.2026;27:259.

Published full text reviewed

Design
Deterministic respiratory-physiology modelling with targeted literature synthesis; no new experimental or clinical data.
Sample
No people, animals or cultured cells. Scenarios are computational assumptions, not trial participants.
Reported result

The same device flow produced different modelled inspired fractions when breathing, capture and reservoir assumptions changed. One no-reservoir example uses H₂ flow 600 mL/min, MIF 30 L/min and capture 0.99 to calculate 1.98% FiH₂; an assumed reservoir adds 0.8 percentage points to 2.78%. These are calculations, not patient measurements. Table 7 reports approximately 261, 520 and 1,200 mL/min for 1%, 2% and 4% FiH₂ in one scenario (MIF 30 L/min, DC 0.4, capture 0.85, retention 0.20); other assumptions give wider ranges. Its coverage percentiles are engineering margins, not measured population percentiles. The paper states that the lowest required FiH₂ has not been directly established in human clinical studies and the framework was not prospectively validated.

HumanInhaled H₂2026

Sixty-minute inhalation of molecular hydrogen decreases blood oxygen saturation but does not alter autonomic cardiac regulation at rest in healthy females

Grepl P et al. · Can J Physiol Pharmacol. 2026;104:1–9.

Design
Randomized double-blind placebo-controlled crossover study
Sample
20 completed both sessions; number initially recruited not reported in the abstract.
Reported result

Mean oxygen saturation was lower with hydrogen (95.9% versus 96.7%; p≤0.007); authors considered the difference clinically insignificant. Heart-rate variability indices did not differ significantly (all p≥0.32). No clinical treatment benefit was tested.

HumanInhaled H₂2026

The combined use of inhaled nitric oxide and molecular hydrogen in patients with post-COVID-19 syndrome

Pozdnyakova DD, Baranova IA, Selemir VD, Medvedev OS, Chuchalin AG. · Ter Arkh. 2026;98(3):147–153.

Design
Randomized open-label controlled study
Sample
60 participants; three groups of 20.
Reported result

Some symptoms, functional and laboratory measures favored the combined group; no serious adverse events were reported.

HumanInhaled H₂2026

The effect of stabilized hydrogen inhalation on clinical and functional parameters in patients with chronic obstructive pulmonary disease

Antipushina DN, Smirnova MI, Gorshkov AYu, Strelkova AV, Ryzhakova LN, Emelyanov AV, Voinova SN, Ignatikova EN, Koshelyaevskaya YaN, Gufranov KF, Drapkina OM. · Russian Journal of Preventive Medicine. 2026;29(6):58–67.

Design
Randomized blinded controlled pilot study
Sample
24 participants; H₂ group 13 and vapor-only group 11.
Reported result

Both groups improved on the primary CAT outcome without a clear between-group advantage; most tests were null, while selected 28-day pulmonary-pressure and walking comparisons favored H₂.