Languages

Read Hydrogenology in your language

Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

Respiratory-physiology modeling of therapeutic hydrogen inhalation: defining the fraction of inspired hydrogen (FiH2) and flow-rate requirements.

LeBaron TW, Ohno K, Salomez-Ihl C, Cinquin P, Boucher F, Sano M, Kheir JN. · Respiratory Research.2026;27:259.

Computational studyInhaled H₂Published 2026Published full text reviewed
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

This modelling study examined why the hydrogen flow shown on a device does not tell us exactly how much hydrogen a person breathes in through a nasal cannula. The calculations varied breathing speed, time spent inhaling, nasal capture and possible gas storage in the upper airway. The same device flow could produce very different inspired hydrogen fractions under different assumptions. The paper recommends reporting the hydrogen fraction in inspired air rather than device flow alone. Its numerical estimates and suggested target concentrations are model outputs and the authors’ interpretation of earlier research. They were not prospectively validated in a new group of patients and do not establish a universal effective or safe dose. An average calculated concentration below the hydrogen flammability limit also does not rule out locally flammable gas around the cannula.

Source data warningAll numerical estimates are model scenarios. They do not establish an effective or safe dose, clinical consensus, or an individual measured FiH₂. Source purity is not inspired concentration. The existing site calculator and guide were not changed.
Evidence type

Computational study

Population or model

Hypothetical low-flow nasal-cannula scenarios varying minute ventilation, inspiratory duty cycle, mean/peak inspiratory flow, nasal capture and reservoir retention.

Intervention and dose

Modelled hydrogen device flow, source fraction and breathing conditions. Suggested 1–4% inspired-hydrogen scenarios are author-proposed interpretations of earlier literature. · Mean inspiratory flow (MIF) = minute ventilation / inspiratory duty cycle (DC). Without a reservoir, FiH₂ ≈ capture efficiency × H₂ flow / MIF. Reservoir contribution depends on retained expiratory gas and tidal volume. Common scenarios use MIF 30 L/min, DC 0.4, capture 0.85, retention 0.20 and reservoir volume 30–40 mL. Henry-law estimates assume temperature, pressure and equilibrium; they are not measured patient concentrations.

Duration

Not applicable; no treatment was administered.

Reported result

The same device flow produced different modelled inspired fractions when breathing, capture and reservoir assumptions changed. One no-reservoir example uses H₂ flow 600 mL/min, MIF 30 L/min and capture 0.99 to calculate 1.98% FiH₂; an assumed reservoir adds 0.8 percentage points to 2.78%. These are calculations, not patient measurements. Table 7 reports approximately 261, 520 and 1,200 mL/min for 1%, 2% and 4% FiH₂ in one scenario (MIF 30 L/min, DC 0.4, capture 0.85, retention 0.20); other assumptions give wider ranges. Its coverage percentiles are engineering margins, not measured population percentiles. The paper states that the lowest required FiH₂ has not been directly established in human clinical studies and the framework was not prospectively validated.

Main limitation

Author-proposed modelling assumptions and concentration targets are not measured patient exposure, established clinical thresholds or dosing guidance.

Evidence and classification

What kind of evidence is this?

Evidence type

Computational study

Reported design

Deterministic respiratory-physiology modelling with targeted literature synthesis; no new experimental or clinical data.

Research topic

Respiratory health

Administration form

Inhaled H₂

Study result signal

Computational model output

Outcome type

Calculated inspired-hydrogen fractions and device-flow requirements under specified assumptions.

Reported in the source

Methods

Population or model

Hypothetical low-flow nasal-cannula scenarios varying minute ventilation, inspiratory duty cycle, mean/peak inspiratory flow, nasal capture and reservoir retention.

Sample

No people, animals or cultured cells. Scenarios are computational assumptions, not trial participants.

Duration

Not applicable; no treatment was administered.

Intervention

Modelled hydrogen device flow, source fraction and breathing conditions. Suggested 1–4% inspired-hydrogen scenarios are author-proposed interpretations of earlier literature.

Hydrogen form

Inhalation-delivery model; no hydrogen administered in this study.

Dose or H₂ specification

Mean inspiratory flow (MIF) = minute ventilation / inspiratory duty cycle (DC). Without a reservoir, FiH₂ ≈ capture efficiency × H₂ flow / MIF. Reservoir contribution depends on retained expiratory gas and tidal volume. Common scenarios use MIF 30 L/min, DC 0.4, capture 0.85, retention 0.20 and reservoir volume 30–40 mL. Henry-law estimates assume temperature, pressure and equilibrium; they are not measured patient concentrations.

Comparator

Reservoir versus no reservoir, differing capture and retention, duty cycles, inspiratory flows, altitude and source-gas configurations.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Calculated inspired-hydrogen fractions and device-flow requirements under specified assumptions.

Reported result

The same device flow produced different modelled inspired fractions when breathing, capture and reservoir assumptions changed. One no-reservoir example uses H₂ flow 600 mL/min, MIF 30 L/min and capture 0.99 to calculate 1.98% FiH₂; an assumed reservoir adds 0.8 percentage points to 2.78%. These are calculations, not patient measurements. Table 7 reports approximately 261, 520 and 1,200 mL/min for 1%, 2% and 4% FiH₂ in one scenario (MIF 30 L/min, DC 0.4, capture 0.85, retention 0.20); other assumptions give wider ranges. Its coverage percentiles are engineering margins, not measured population percentiles. The paper states that the lowest required FiH₂ has not been directly established in human clinical studies and the framework was not prospectively validated.

Extraction completeness

Complete published full text reviewed. Source contradictions and unreported details remain explicit; no independent reanalysis was performed.

Reported adverse events

Not applicable to a computational study; no treatment or safety experiment.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

This is targeted narrative modelling, not a systematic meta-analysis or dosing trial. Capture and reservoir retention were assumed or bounded using oxygen-delivery literature, without an H₂-specific measured distribution. The proposed approximately 1% minimum and 2–4% window are interpretations, not universal consensus thresholds. Henry-law plasma/tissue estimates assume equilibration. Figure 4 panel descriptions and some Table 6 duty-cycle labels are inconsistent; Figure 2 shows a 4% baseline into expiration, which is not an inspired-gas measurement. Average FiH₂ below 4% does not eliminate locally flammable gas around pure-H₂ cannulas. No independent computation, safety-engineering validation or site-calculator audit was performed.

Applies directly to

Computational hypothesis or model output, not evidence of clinical efficacy or safety.

Funding and support

JNK reports NIH/NHLBI 4R33HL164373 and 1R01HL175158-01, and NIH/NICHD 1R43HD116647-01.

Conflicts of interest

TWL is Scientific Officer of InhaleH2.com. MS reports advisory fees and research funding from DoctorsMan Co Ltd. JNK reports federal grants. Other authors declare no conflicts.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

PMID: 42050516 · DOI: 10.1186/s12931-026-03664-9

Publisher access

Published open-access full text in PMC.

Editorial verification

Source verification based on the supplied complete full-text review. This is not independent medical or statistical validation.

Source sections checked

Complete main text, figures, tables and funding/conflict disclosures. No independent statistical validation.

Extraction basis

Complete published full-text article reviewed, including methods, results, tables, figures, discussion and disclosures.

Last reviewed

17 November 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy

Send the exact difference between this page and the linked source. The study reference is attached automatically.