Hydrogen inhalation is associated with a transient rightward shift in prefrontal oxyhemoglobin asymmetry and autonomic modulation
Moriya M, Oyama K, Den Y, Yamada Y, Sakatani K. · Scientific reports. 2026;16(1):6202.
Study at a glance
Human
Healthy adults, not patients with a neurological condition.
Nasal cannula hydrogen while breathing room air. · Source purity 99.9%; cannula flow 300 mL/min. Neither is a measured inspired concentration.
One 30-minute session; post-session measurements through 90 minutes.
Oxyhemoglobin asymmetry shifted transiently rightward; the 9-person sensitivity comparison was not significant. Deoxyhemoglobin asymmetry and mean blood pressure showed no significant changes. Heart rate decreased. These physiological observations do not establish clinical benefit.
Small uncontrolled study; influential cases, time/position effects and unknown inspired exposure limit inference. Y. Den represents the device manufacturer; CX Wellness supported the study.
What kind of evidence is this?
Human
Exploratory single-arm physiological pilot; no sham or parallel control; not an RCT
Other neurological conditions
Inhaled H₂
Information not yet classified
Some editorial classification fields are still pending. The source-reported outcomes and result are shown below; Hydrogenology does not infer a positive or negative signal from prose automatically.
Methods
Healthy adults, not patients with a neurological condition.
15 recruited; 11 in TD-NIRS analysis after four quality-control exclusions; 9 in an influential-case sensitivity analysis.
One 30-minute session; post-session measurements through 90 minutes.
Nasal cannula hydrogen while breathing room air.
99.9% H₂ purity at source; inspired fraction not measured.
Source purity 99.9%; cannula flow 300 mL/min. Neither is a measured inspired concentration.
Cannula source gas: 300 mL/min.
Inspired oxygen and SpO₂ not measured.
Within-person baseline; no sham/control group.
Outcomes and reported result
Prefrontal hemoglobin asymmetry and ECG-derived autonomic measures; no cognitive performance endpoint.
Oxyhemoglobin asymmetry shifted transiently rightward; the 9-person sensitivity comparison was not significant. Deoxyhemoglobin asymmetry and mean blood pressure showed no significant changes. Heart rate decreased. These physiological observations do not establish clinical benefit.
Original editorial summary checked against the main full article; supplementary files and protocol history were not fully reviewed.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Small uncontrolled study; influential cases, time/position effects and unknown inspired exposure limit inference. Y. Den represents the device manufacturer; CX Wellness supported the study.
Acute physiological observations in healthy adults only.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 41582106 · DOI: 10.1038/s41598-026-36599-8
A free full article is available through PubMed Central.
Hydrogenology editorial · AI-assisted source comparison; main full text, relevant methods/results/discussion · 23 October 2026. No independent clinician review or formal GRADE assessment.
Participants; Hydrogen inhalation protocol; Exploratory data quality control; Results; sensitivity analysis; Discussion; competing interests
Prior automated full-text extraction retained; AI-assisted editorial comparison on 23 October 2026: Participants; Hydrogen inhalation protocol; Exploratory data quality control; Results; sensitivity analysis; Discussion; competing interests. Source: https://www.nature.com/articles/s41598-026-36599-8. Earlier automated extraction is not independent editorial review.
23 October 2026
Help people check the facts before they buy.
Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.