Model information
Price not confirmed- Manufacturer/seller market
- Australia
- Manufacturing origin
- Handmade in Australia, supplier declaration; supply chain not independently audited
- Technology
- PEM electrolysis, according to supplier
- Required water
- Pure distilled water; source specifies TDS below 2 ppm and conductivity below 2µS/cm. The supplier excludes tap water.
- Generation additives and consumables
- ION filter and dehumidification canister/beads mentioned. No added generation chemical confirmed. KOH/NaOH use, factory fill, user addition and replacement remain unconfirmed. Dehumidifier beads are not evidence of a generation additive.
- H₂ generation / flow
- H₂-only flow not separately specified. Total output conflicts between product page and linked 2025brochure.
- Total generated output
- Product page: up to 1,400 mL/min combined; linked 2025brochure: up to 1,600 mL/min combined. Exact revision requires confirmation.
- Declared gas configuration
- Mixture-only
- Outlet claim (not inspired concentration)
- 66.6%
- Prepared-air concentration claim
- Not established
- Concentration limits
- 66.6%H₂ /33.3%O₂ describes supplier-declared combined-gas composition, not actual inspired concentration.
- Price context
- Current price could not be confirmed on 2 November 2026: the manufacturer links this exact model to its store, but the store returned HTTP 503 or timed out. Older symbol-only amounts are not current confirmed prices; currency, GST and delivered totals remain unresolved.
- Availability
- Current ordering availability and exact revision unconfirmed
- Source status
- Exact model page and2025official brochure checked. Commercial specifications only, no independent test.
- Last source check
- 2026-10-29
- Field-specific dates
- priceReview: 2026-11-02
- Notes and unresolved claims
- Unresolved model/revision conflict in output and dimensions between page and brochure; both values retained. No KOH claim is confirmed. Current ordering availability and exact revision remain unconfirmed.
Source links
- Supplier exact model page
- Linked2025manufacturer brochure
- Price-only review — brand/manufacturer direct — 2 November 2026
The documentation level and original check dates above are retained. Listing a source does not mean every linked manual or report was read, nor that Hydrogenology verified supplier test claims.
Reader experiences
Only email-confirmed, moderator-approved ratings contribute. Email verification does not verify ownership or prove performance/safety. Comments may be submitted without a rating.
Rate or comment on this model
Request independent testing of this model
This uses the existing verified-request system. Exact aliases are reconciled with historical requests; one verified email counts once per model.
Before interpreting a specification
Source output, gas purity, mixed-gas composition and actual inspired exposure are different. Generator production of H₂ and O₂ alone does not establish their coadministration.