MiZ Jobs-α+ / Jobs-α+ Lite
Supplier specifications and source limits, not an independent Hydrogenology test or a medical recommendation.
Model information
Price not confirmed- Manufacturer/seller market
- Japan
- Manufacturing origin
- Manufacturing country not independently established
- Technology
- Electrolytic hydrogen generation with air dilution; exact membrane not established.
- Required water
- Purified water supplied with unit
- Generation additives and consumables
- Purified-water cartridge replacement at 500 hours; cannulas and water.
- H₂ generation / flow
- α+:300 mL/min; Lite:150 mL/min H₂
- Total generated output
- Dilution air about 4,000 mL/min in both variants; generated H₂ is additional.
- Declared gas configuration
- Separate H₂ / optional combined mode
- Outlet claim (not inspired concentration)
- Not established
- Prepared-air concentration claim
- Jobs-α+: 7%; Jobs-α+ Lite: 3.6%; discrete supplier claims, not actual inspired exposure
- Concentration limits
- Two distinct models: Jobs-α+ declares 7%; Jobs-α+ Lite declares 3.6%. These are separate declared values, not a continuous 3.6–7% range. Actual inhaled concentration is not established here.
- Variants
- Model: Jobs-α+; H₂ generation (mL/min): 300; Prepared concentration (%): 7 | Model: Jobs-α+ Lite; H₂ generation (mL/min): 150; Prepared concentration (%): 3.6
- Price context
- Manufacturer gives only an approximate family price indication in the JPY 500,000s to around JPY 1,000,000, including tax, depending on conditions. No fixed Jobs-α+ versus Lite model quote was established, so no numeric comparison price is assigned. Consumable prices are separate.
- Availability
- Not independently confirmed
- Source status
- Primary supplier documentation read; specifications are supplier claims, not independent performance or medical validation.
- Last source check
- 2026-10-29
- Field-specific dates
- priceReview: 2026-11-02
- Notes and unresolved claims
- Two separate prepared-mixture claims are documented: Jobs-α+ about 7%; Jobs-α+ Lite about 3.6%. These are discrete variants, not a continuously adjustable 3.6–7% operating range. Neither value establishes safety or actual inspired exposure.
Source links
The documentation level and original check dates above are retained. Listing a source does not mean every linked manual or report was read, nor that Hydrogenology verified supplier test claims.
Reader experiences
Only email-confirmed, moderator-approved ratings contribute. Email verification does not verify ownership or prove performance/safety. Comments may be submitted without a rating.
Rate or comment on this model
Request independent testing of this model
This uses the existing verified-request system. Exact aliases are reconciled with historical requests; one verified email counts once per model.
Before interpreting a specification
Source output, gas purity, mixed-gas composition and actual inspired exposure are different. Generator production of H₂ and O₂ alone does not establish their coadministration.