Hydrogenology
Hydrogenology editorial study record

Hydrogen-rich water suppresses the reduction in blood total antioxidant capacity induced by 3 consecutive days of severe exercise in physically active males

Dobashi S et al. · Med Gas Res. 2020;10(1):21–26.

HumanH₂-rich waterPublished 2020
Study record, not medical adviceThis page reports one source and Hydrogenology’s source-text extraction. It does not establish that molecular hydrogen is effective, safe or appropriate for any person. Human, animal and laboratory evidence must not be treated as equivalent.
Source and classification

What kind of evidence is this?

Evidence stream

Human

Reported design

Randomized single-blind controlled crossover repeated-measures study

Research topic

Exercise and recovery

Administration classification

H₂-rich water

Study result signal

Not reported in this record.

Outcome type

Not reported in this record.

Reported in the source

Methods at a glance

Population or model

Healthy physically active young men

Sample

8 participants

Duration

Three consecutive exercise days in each condition, with at least a 1-week crossover interval

Intervention

500 mL hydrogen-rich water within 5 minutes before exercise and another 500 mL after exercise on each of 3 consecutive days

Hydrogen form

H₂ dissolved in water — H₂ only, not Brown’s gas.

H₂ specification

5.14 ± 0.03 ppm dissolved H₂ immediately before drinking.

H₂ flow

Not applicable — oral water, not gas inhalation.

O₂ delivered with H₂

No O₂ was co-delivered as part of the intervention.

Comparator

Placebo tap water with 0.00 ± 0.00 ppm H₂, prepared in a similar container

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Countermovement jump, knee-extensor strength, sprint-cycling power, lactate and serum redox markers

Reported result

Exercise-performance and lactate outcomes did not differ between water conditions. The H₂-water condition attenuated the reduction in the BAP/d-ROM redox ratio observed across consecutive exercise days, but baseline imbalance complicated interpretation.

Results-extraction completeness

Preparation, dose, outcome tables, limitations and disclosures checked in the open-access full text; independent appraisal remains incomplete.

A reported association, difference or mechanism is not automatically a clinical benefit. Null findings, outcome type, study design and precision all matter.

Interpretation limits

Cautions and applicability

Design and reporting cautions

Only eight men, single blinding, no performance decrement induced by the protocol, and an unexpected baseline difference in the main redox ratio. The manufacturer supplied the hydrogen-generating kits.

Applies directly to

Healthy physically active young men completing the reported 3-day sprint-cycling protocol.

Preliminary appraisal framework

Not reported in this record.

Preliminary risk-of-bias status

Not reported in this record.

Appraisal rationale

Not reported in this record.

No single-study GRADE certainty rating is assigned. Certainty is assessed by important outcome across a complete eligible evidence set, not by attaching a final grade to one source.

Provenance

Sources and record status

Identifiers

PMID: 32189665 · DOI: 10.4103/2045-9912.279979

Publisher access

Open-access full text is available through PMC.

Extraction basis

Open-access PMC full text, PubMed record and CiNii bibliographic record.

Record revision

2026-08-10