Silicon nanoparticles for oral administration of molecular hydrogen.
Hennie Marie Johnsen, Werner Filtvedt, Marianne Hiorth, Jo Klaveness · International journal of pharmaceutics. 2022;629:122371.
Study at a glance
Preclinical
Laboratory formulation and simulated gastrointestinal exposure study.
Silicon particles tested for H₂ generation across media and pH conditions. · See the intervention description and source methods for study-specific H₂ specifications.
See the source timeline for component-specific durations.
Hydrogen generation reached approximately 1310 mL/g at pH 7.4 under the tested conditions. Gastric pretreatment did not reduce the measured generation. Surfactants hindered it and proteins slowed it.
Bench measurements do not establish delivered dose or safety in people. Three authors reported inventorship on a patent application.
What kind of evidence is this?
Preclinical
Laboratory formulation and simulated gastrointestinal exposure study.
Other molecular hydrogen research
Other forms
Information not yet classified
Some editorial classification fields are still pending. The source-reported outcomes and result are shown below; Hydrogenology does not infer a positive or negative signal from prose automatically.
Methods
Laboratory formulation and simulated gastrointestinal exposure study.
See the article for assay- or arm-specific sample sizes.
See the source timeline for component-specific durations.
Silicon particles tested for H₂ generation across media and pH conditions.
Other forms
See the intervention description and source methods for study-specific H₂ specifications.
Comparisons across simulated gastric pretreatment, buffer conditions and media components.
Outcomes and reported result
Hydrogen generation reached approximately 1310 mL/g at pH 7.4 under the tested conditions. Gastric pretreatment did not reduce the measured generation. Surfactants hindered it and proteins slowed it.
Hydrogen generation reached approximately 1310 mL/g at pH 7.4 under the tested conditions. Gastric pretreatment did not reduce the measured generation. Surfactants hindered it and proteins slowed it.
Editorial extraction of main findings; see the source for individual comparisons.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Bench measurements do not establish delivered dose or safety in people. Three authors reported inventorship on a patent application.
Population and experimental conditions studied in the source.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 36351504 · DOI: 10.1016/j.ijpharm.2022.122371
Complete main article or author manuscript consulted.
Full-text editorial extraction (main article). Main article methods, reported outcomes and limitations. Supplements were not systematically independently reviewed.
24 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 828 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.