The Evaluation and Quantitation of Dihydrogen Metabolism Using Deuterium Isotope in Rats
Hyspler R, Ticha A, Schierbeek H, Galkin A, Zadak Z. · PLOS ONE. 2015;10(6):e0130687.
Study at a glance
This laboratory study used deuterium, a stable form of hydrogen, to trace gas metabolism in 24 rats. About one tenth of the administered tracer was calculated to become part of body water under room-air conditions. The result changed with oxygen exposure and varied substantially between animals. Separate experiments in isolated bovine-heart material found less superoxide production after hydrogen exposure. The tracer was injected into the abdomen, not inhaled or drunk. These findings do not tell us how long ordinary hydrogen remains in a person's body or establish a health benefit. The low-oxygen animal group died during the experiment, probably from combined hypoxia and anesthesia, and did not complete follow-up.
Preclinical
Male Wistar rats receiving an intraperitoneal D₂ tracer and isolated bovine-heart mitochondrial particles exposed to H₂.
Rats received 2 mL triple-washed D₂ intraperitoneally each hour at times 0–5 h (six intended administrations) under room air, endotoxin challenge, hyperoxia or hypoxia. Endotoxin 1 mg in 500 µL intraperitoneally. Source expresses oxygen conditions as approximately 21, 100 and 10.5 kPa under normal pressure, i.e. approximately air/pure oxygen/half-normal oxygen; those are oxygen partial pressures, despite its FiO₂ wording. D₂ is a stable isotope tracer, not ordinary H₂. In vitro reaction mixture was gently flushed with H₂ for 6 min before mitochondrial particles/NADH were added; achieved dissolved H₂ concentration was not specified. · 2 mL washed D₂ intraperitoneally each hour at 0–5 hours; not ordinary H₂ inhalation or drinking water. In vitro mixtures were flushed with H₂ for six minutes, without a specified dissolved concentration. Oxygen conditions were printed as partial pressures around 21, 100 and 10.5 kPa, despite FiO₂ wording.
Intended 6 h tracer experiment with blood sampling every 2 h; hypoxia group terminated at 4 h after animal deaths. In vitro rate measurements followed H₂ pretreatment.
In air-breathing rats, median calculated oxidized fractions in the reported 2 h intervals were 9.1%, 11.6% and 9.5%. Hyperoxia values were 3.0%, 12% and 2.5%; differences were marked significant at 2 h and 6 h, not 4 h. Endotoxin/hypoxia differences were not statistically significant relative to air controls. The approximately 10% result is model- and assumption-dependent D₂ oxidation, not direct proof of a corresponding human H₂ fraction. Peripheral blood D₂ gas was not measurably significant; local peritoneal-layer and liver concentrations were 355±114 and 244±36 µmol/L respectively. The authors interpret rapid lung elimination as a likely explanation but did not measure a human elimination half-life. In isolated bovine-heart particles, H₂-flushed mixture reduced measured superoxide production from 2.33±0.19 to 1.57±0.25 nmol/min/mg (P=0.0002). The paper explores possible iron/complex-I interactions; this does not establish the exact mechanism or a clinical benefit.
Small groups, large between-animal scatter, intraperitoneal route and stable-isotope kinetics limit generalization to ordinary H₂ inhalation or drinking water in people.
What kind of evidence is this?
Preclinical
Four rat physiology groups receiving intraperitoneal deuterium gas (D₂), with isotope enrichment of body water and tissue gas measured; complementary H₂ exposure of isolated bovine-heart submitochondrial particles. Allocation randomization/blinding not clearly reported.
Other molecular hydrogen research
Other forms
Mixed preclinical findings
D₂ enrichment of body water, calculated fraction of administered D₂ oxidized to water, tissue/blood D₂ concentrations, and mitochondrial-complex-I superoxide generation rate.
Methods
Male Wistar rats receiving an intraperitoneal D₂ tracer and isolated bovine-heart mitochondrial particles exposed to H₂.
24 male Wistar rats, 230–280 g, four groups of six. In vitro: three experiments using two bovine-heart submitochondrial particle preparations. No human participants.
Intended 6 h tracer experiment with blood sampling every 2 h; hypoxia group terminated at 4 h after animal deaths. In vitro rate measurements followed H₂ pretreatment.
Rats received 2 mL triple-washed D₂ intraperitoneally each hour at times 0–5 h (six intended administrations) under room air, endotoxin challenge, hyperoxia or hypoxia. Endotoxin 1 mg in 500 µL intraperitoneally. Source expresses oxygen conditions as approximately 21, 100 and 10.5 kPa under normal pressure, i.e. approximately air/pure oxygen/half-normal oxygen; those are oxygen partial pressures, despite its FiO₂ wording. D₂ is a stable isotope tracer, not ordinary H₂. In vitro reaction mixture was gently flushed with H₂ for 6 min before mitochondrial particles/NADH were added; achieved dissolved H₂ concentration was not specified.
Injected deuterium gas (D₂) tracer in rats; separate hydrogen-flushed in vitro mitochondrial mixtures.
2 mL washed D₂ intraperitoneally each hour at 0–5 hours; not ordinary H₂ inhalation or drinking water. In vitro mixtures were flushed with H₂ for six minutes, without a specified dissolved concentration. Oxygen conditions were printed as partial pressures around 21, 100 and 10.5 kPa, despite FiO₂ wording.
Room-air rats receiving the same D₂ tracer versus endotoxin, hyperoxia and hypoxia groups. In vitro H₂-flushed versus untreated reaction mixtures with superoxide-dismutase checks; no human inhalation comparison.
Outcomes and reported result
D₂ enrichment of body water, calculated fraction of administered D₂ oxidized to water, tissue/blood D₂ concentrations, and mitochondrial-complex-I superoxide generation rate.
In air-breathing rats, median calculated oxidized fractions in the reported 2 h intervals were 9.1%, 11.6% and 9.5%. Hyperoxia values were 3.0%, 12% and 2.5%; differences were marked significant at 2 h and 6 h, not 4 h. Endotoxin/hypoxia differences were not statistically significant relative to air controls. The approximately 10% result is model- and assumption-dependent D₂ oxidation, not direct proof of a corresponding human H₂ fraction. Peripheral blood D₂ gas was not measurably significant; local peritoneal-layer and liver concentrations were 355±114 and 244±36 µmol/L respectively. The authors interpret rapid lung elimination as a likely explanation but did not measure a human elimination half-life. In isolated bovine-heart particles, H₂-flushed mixture reduced measured superoxide production from 2.33±0.19 to 1.57±0.25 nmol/min/mg (P=0.0002). The paper explores possible iron/complex-I interactions; this does not establish the exact mechanism or a clinical benefit.
Main full text reviewed; isotope-tracer and isolated-enzyme results distinguished from human H₂ kinetics. Source inconsistencies, null results and unreported values are retained; no independent reanalysis.
Hypoxia experiments stopped after 4 h because animals died, attributed by the authors to combined hypoxia and repeated anesthesia causing apnea. This is not demonstrated D₂ toxicity, and the experiment is not a comprehensive safety study.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Small groups, large between-animal scatter, intraperitoneal route and stable-isotope kinetics limit generalization to ordinary H₂ inhalation or drinking water in people. Calculated oxidation assumes body water equals 66% of weight and specified tracer distribution/fates. Isotope effects and variable absorption/respiratory loss introduce uncertainty; authors estimate H₂ could react 10–20% faster than D₂, but this extrapolation is not directly measured human kinetics. Hypoxic animals died; missing 6 h data and repeated-anesthesia effects limit oxygen-condition comparisons. Only three in vitro experiments from two particle preparations; H₂ dose in solution not quantified; gas flushing may affect the mixture's gas composition. Clinical efficacy, retention time and broad nontoxicity claims are not established by this study.
The population or experimental model and protocol described here; clinical benefit and general safety are not established.
Czech Ministry of Health NT 13 536-4/12; UK Medical Research Council G 1100051 and MR/L 007339/1. Funders reportedly had no role in design, data, publication decision or manuscript.
Authors declare no competing interests.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 26103048 · DOI: 10.1371/journal.pone.0130687
Published main full text available through the linked original source.
Source verification based on the supplied publication review. This is editorial extraction, not independent medical or statistical validation.
Entire PMC main text read including Table 1 and figure legends 1–3, detailed isotope methods/calculation, results/discussion/disclosures/references. Data availability says all relevant data are within the paper; no separate supplement identified. No independent raw-data or mass-spectrometry reanalysis.
Complete published main full-text article reviewed. Supplementary review scope is stated separately; no independent medical, statistical or image-forensic validation.
22 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.