Languages

Read Hydrogenology in your language

Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

Convenient methods for ingestion of molecular hydrogen: drinking, injection, and inhalation

Kurokawa R, Seo T, Sato B, Hirano S, Sato F. · Medical Gas Research. 2015;5:13.

PreclinicalOther formsPublished 2015Complete main article, seven figure captions, container table and disclosures reviewed. No separate supplement identified. Figures were read through captions/text, not independently digitized or visually audited.
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

Researchers measured how experimental devices produced and retained hydrogen in water, sealed fluids and a gas stream. Two pressurized water systems reached roughly 7–10 mg/L, with losses after opening. A gas device maintained about 3% hydrogen output for three hours. These were laboratory concentration measurements: no people or animals received treatment in this report. The study does not establish health benefits, medical sterility, safe home preparation or the performance of other devices. All authors worked for the company developing the tested apparatuses.

Source data warningOriginal bench measurements, with no administered human or animal treatment. Output concentration stability is not clinical efficacy, sterility, approved shelf life or safe home preparation. All authors had MiZ company affiliations.
Evidence type

Preclinical

Population or model

Bench concentration and storage measurements in water, saline and gas systems; no treated people or animals.

Intervention and dose

Two pressurized hydrogen-water preparation systems; permeation of hydrogen into sealed fluid containers; separate sealed storage approach; electrolysis-derived hydrogen diluted into air. These are experimental preparation methods, not approved clinical directions or consumer-device recommendations. · Two pressurized hydrogen-water preparation systems; permeation of hydrogen into sealed fluid containers; separate sealed storage approach; electrolysis-derived hydrogen diluted into air. These are experimental preparation methods, not approved clinical directions or consumer-device recommendations.

Duration

Water concentration measured over preparation and up to seven days sealed / hours after opening; saline storage up to 12 months; gas concentration stability up to three hours.

Reported result

Two sealed-water systems reached 7.13 ± 0.22 and 10.08 ± 0.34 mg/L after 24 hours; after seven days unopened, reported concentrations were 8.30 ± 0.98 and 10.10 ± 0.21 mg/L. Concentrations declined after opening. These values describe these pressurized experimental systems, not all marketed hydrogen-water bottles. Hydrogen permeation into infusion containers depended on material, thickness and fluid. Approximately 1.0 mg/L was obtained after ten hours immersion; after removal, concentration fell to approximately 0.6 mg/L within one hour in the described condition. Some fluids/containers admitted hydrogen poorly. Concentrations in separately packaged sealed containers were retained over 12 months in individual measurements; this did not establish maintained sterility, chemical purity, clinical shelf life or regulatory approval. Gas output was 2.91 ± 0.08% hydrogen after 30 seconds and remained approximately 3% for three hours. No significant time-point difference was reported. This is device-output stability, not measured inspired concentration or human safety evidence.

Main limitation

Small laboratory measurement series; several fluid measurements are single observations with limited reproducibility assessment.

Evidence and classification

What kind of evidence is this?

Evidence type

Preclinical

Reported design

Laboratory comparison of hydrogen preparation and storage methods. Publication carries a Study Protocol heading but reports original experimental concentration measurements; not a randomized efficacy trial or pharmacokinetic animal experiment.

Research topic

Other molecular hydrogen research

Administration form

Other forms

Study result signal

Bench concentration/stability measurements; no clinical outcomes

Outcome type

Hydrogen concentration in water/fluids and gas under the specific experimental conditions; not symptom improvement, human tissue exposure or comprehensive device safety.

Reported in the source

Methods

Population or model

Bench concentration and storage measurements in water, saline and gas systems; no treated people or animals.

Sample

No treated human participants or animals. Water experiments generally 3–5 independent measurements; gas stability n=3; saline/container results are individual measurements. Do not count cited earlier clinical studies as participants in this report.

Duration

Water concentration measured over preparation and up to seven days sealed / hours after opening; saline storage up to 12 months; gas concentration stability up to three hours.

Intervention

Two pressurized hydrogen-water preparation systems; permeation of hydrogen into sealed fluid containers; separate sealed storage approach; electrolysis-derived hydrogen diluted into air. These are experimental preparation methods, not approved clinical directions or consumer-device recommendations.

Hydrogen form

Experimental preparation and concentration/stability measurements across water, fluids and gas; no treatment administered.

Dose or H₂ specification

Two pressurized hydrogen-water preparation systems; permeation of hydrogen into sealed fluid containers; separate sealed storage approach; electrolysis-derived hydrogen diluted into air. These are experimental preparation methods, not approved clinical directions or consumer-device recommendations.

Comparator

Temperature, preparation time, opening/storage duration and container/fluid type comparisons; no patient placebo arm or disease model.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Hydrogen concentration in water/fluids and gas under the specific experimental conditions; not symptom improvement, human tissue exposure or comprehensive device safety.

Reported result

Two sealed-water systems reached 7.13 ± 0.22 and 10.08 ± 0.34 mg/L after 24 hours; after seven days unopened, reported concentrations were 8.30 ± 0.98 and 10.10 ± 0.21 mg/L. Concentrations declined after opening. These values describe these pressurized experimental systems, not all marketed hydrogen-water bottles. Hydrogen permeation into infusion containers depended on material, thickness and fluid. Approximately 1.0 mg/L was obtained after ten hours immersion; after removal, concentration fell to approximately 0.6 mg/L within one hour in the described condition. Some fluids/containers admitted hydrogen poorly. Concentrations in separately packaged sealed containers were retained over 12 months in individual measurements; this did not establish maintained sterility, chemical purity, clinical shelf life or regulatory approval. Gas output was 2.91 ± 0.08% hydrogen after 30 seconds and remained approximately 3% for three hours. No significant time-point difference was reported. This is device-output stability, not measured inspired concentration or human safety evidence.

Extraction completeness

Complete main article, seven figure captions, container table and disclosures reviewed. No separate supplement identified. Figures were read through captions/text, not independently digitized or visually audited. No separate supplement identified in the reviewed main article. Null findings, discrepancies and unreported values are retained; no independent reanalysis.

Reported adverse events

Not applicable as a clinical adverse-event assessment; no clinical safety conclusion supported.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

Small laboratory measurement series; several fluid measurements are single observations with limited reproducibility assessment. No treated participants or animals, clinical efficacy outcomes, actual inspired dose, tissue pharmacokinetics, broad contaminant testing or comprehensive safety assessment. All authors were affiliated with MiZ Co., Ltd. and developed the devices; authors nevertheless declared no competing interests. Preserve both facts. Hydrogen concentration retention does not establish validated medical sterility, approved storage period or suitability for self-prepared infusions. The article calls below-4% gas safe relative to a stated detonation limit; this is not a universal clinical safety threshold. Do not present the preparation recipes as home-use instructions. Figure findings checked against textual captions/results; plots were not independently digitized or visually audited in this review.

Applies directly to

The reported population or experimental model and protocol only; clinical benefit and general safety are not established.

Funding and support

No explicit funding statement identified.

Conflicts of interest

Authors declared no competing interests; all author affiliations were MiZ Co., Ltd., and authors developed/prepared the tested apparatuses.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

PMID: 26504515 · DOI: 10.1186/s13618-015-0034-2

Publisher access

Published main full text available through the linked original source.

Editorial verification

Editorial integration of the supplied source review; not independent medical or statistical validation.

Source sections checked

Complete cached official full main XML including introduction, methods, all results and seven figure captions/container table, conclusion, disclosures and 18 references read. No supplementary material identified; no independent plot/image or raw-data audit. Supplementary scope: No separate supplement identified in the reviewed main article.

Extraction basis

Complete published main full-text article reviewed using the supplied study-specific packet. Supplementary scope is stated separately; no independent medical, statistical or image-forensic validation.

Registry / related-source limitations

Ethics and consent: No human/animal administration reported in the article; no clinical ethics approval identified or inferred. Related-data limitations: No participant/animal cohort in this technical report. Cited human disease studies and the separate rat-tissue study PMID 24975958 are background, not new independent data here. Do not attribute those efficacy/PK outcomes to this article.

Last reviewed

24 November 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 761 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy

Send the exact difference between this page and the linked source. The study reference is attached automatically.