Pharmacokinetics of a single inhalation of hydrogen gas in pigs
Sano M, Ichihara G, Katsumata Y, Hiraide T, Hirai A, Momoi M, Tamura T, Ohata S, Kobayashi E. · PloS one. 2020;15(6):e0234626.
Study at a glance
Preclinical
Two healthy female pigs weighing22.4 and 22.0 kg, anaesthetized, intubated and undergoing open-chest instrumentation.
Lungs manually emptied and inflated once with pure hydrogen, held at inspiration about 30 seconds, then ordinary mechanical ventilation resumed. 100%H₂ delivered from a filled ball at approximately 20mmHg inflation pressure; exact gas volume unreported. This invasive experimental method is not a consumer-inhalation protocol.
About30 seconds per exposure; blood sampling through60 minutes in first session and 10 minutes in second.
Arterial H₂ rose rapidly after the single inflation and then fell, with a reported half-life of 92 seconds versus 310–350 seconds in sampled veins. Arterial levels were nearly back to baseline by60 minutes, while venous H₂ remained detectable above baseline. Only two pigs were studied, and tissue uptake/metabolism was inferred from blood differences rather than measured directly. The study did not test disease benefit or establish how long H₂ remains in every human tissue.
Two animals with repeated/technical samples, non-physiological pure-H₂ lung inflation, surgery and anaesthesia; tissue retention and metabolism are inferences. No human or efficacy endpoint.
What kind of evidence is this?
Preclinical
Exploratory pharmacokinetic experiment with repeated measurements in two surgically instrumented pigs; no efficacy trial.
Other molecular hydrogen research
Inhaled H₂
Information not yet classified
Some editorial classification fields are still pending. The source-reported outcomes and result are shown below; Hydrogenology does not infer a positive or negative signal from prose automatically.
Methods
Two healthy female pigs weighing22.4 and 22.0 kg, anaesthetized, intubated and undergoing open-chest instrumentation.
Two pigs; two exposure sessions per pig. Duplicate blood measurements are technical repeats, not additional animals.
About30 seconds per exposure; blood sampling through60 minutes in first session and 10 minutes in second.
Lungs manually emptied and inflated once with pure hydrogen, held at inspiration about 30 seconds, then ordinary mechanical ventilation resumed.
Single controlled intratracheal inflation with 100%H₂.
100%H₂ delivered from a filled ball at approximately 20mmHg inflation pressure; exact gas volume unreported. This invasive experimental method is not a consumer-inhalation protocol.
Within-animal pre-exposure baseline and arterial/portal/hepatic-venous sampling sites; no separate untreated group.
Outcomes and reported result
Blood H₂ concentration and time course by gas chromatography at three vascular sites.
Arterial H₂ rose rapidly after the single inflation and then fell, with a reported half-life of 92 seconds versus 310–350 seconds in sampled veins. Arterial levels were nearly back to baseline by60 minutes, while venous H₂ remained detectable above baseline. Only two pigs were studied, and tissue uptake/metabolism was inferred from blood differences rather than measured directly. The study did not test disease benefit or establish how long H₂ remains in every human tissue.
Full-text editorial review; study-specific methods and outcomes checked.
No dedicated safety analysis was reported for this invasive, anaesthetized preparation.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Two animals with repeated/technical samples, non-physiological pure-H₂ lung inflation, surgery and anaesthesia; tissue retention and metabolism are inferences. No human or efficacy endpoint.
Blood hydrogen kinetics in this two-pig experimental preparation.
Supported by SESA Corporation (E.K.); Sou Hashimoto of Doctors Man Co., Ltd. provided the H2 filling device. Authors disclosed Doctors Man advisory fees, Taiyo Nippon Sanso advisory/research fees and hydrogen-related patents; S.O. was founder/CEO of Mitos. The funders were declared to have no role in design, collection, analysis or publication decisions.
Supported by SESA Corporation (E.K.); Sou Hashimoto of Doctors Man Co., Ltd. provided the H2 filling device. Authors disclosed Doctors Man advisory fees, Taiyo Nippon Sanso advisory/research fees and hydrogen-related patents; S.O. was founder/CEO of Mitos. The funders were declared to have no role in design, collection, analysis or publication decisions.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 32559239 · DOI: 10.1371/journal.pone.0234626
A free full article is available through PubMed Central.
AI-assisted editorial review of the original full-text methods, results, limitations and disclosures for the specified replacement fields; not independent clinical or statistical validation.
Methods; Results and figure/table captions; Discussion; funding and conflicts
Primary full text: Methods, Results, figure/table captions, Discussion and funding/conflict statements reviewed; no human treatment effect inferred.