Hydrogenology
Hydrogenology editorial study record

Low-Flow Nasal Cannula Hydrogen Therapy

Sano M et al. · J Clin Med Res. 2020;12(10):674–680.

PreclinicalInhaled H₂Published 2020
Study record, not medical adviceThis page reports one source and Hydrogenology’s source-text extraction. It does not establish that molecular hydrogen is effective, safe or appropriate for any person. Human, animal and laboratory evidence must not be treated as equivalent.
Source and classification

What kind of evidence is this?

Evidence stream

Preclinical

Reported design

Uncontrolled large-animal pharmacokinetic feasibility experiment

Research topic

Respiratory health

Administration classification

Inhaled H₂

Study result signal

Not reported in this record.

Outcome type

Not reported in this record.

Reported in the source

Methods at a glance

Population or model

Spontaneously breathing micro miniature pigs

Sample

3 pigs

Duration

Measurements during the first hour of inhalation

Intervention

100% H₂ through a nasal cannula with a separate oxygen mask

Hydrogen form

H₂ alone from the generator; O₂ was supplied separately, not generated as Brown’s gas.

H₂ specification

100% H₂ source gas.

H₂ flow

250 mL/min H₂, directly reported.

O₂ delivered with H₂

O₂ was delivered separately by veterinary anesthesia equipment; the O₂ flow was not reported.

Comparator

No concurrent control group

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Arterial blood H₂ concentration and saturation; delivery feasibility

Reported result

Arterial H₂ concentrations rose during low-flow delivery in all three pigs. This was a delivery and pharmacokinetic experiment, not a disease-treatment or human clinical study.

Results-extraction completeness

Flow, device, methods, results, patents and conflicts checked in the free full text; independent appraisal remains incomplete.

A reported association, difference or mechanism is not automatically a clinical benefit. Null findings, outcome type, study design and precision all matter.

Interpretation limits

Cautions and applicability

Design and reporting cautions

Only three pigs, no comparator and no clinical outcome. Authors disclosed multiple patents related to H₂ delivery; the result cannot establish efficacy in people.

Applies directly to

Technical low-flow nasal-cannula delivery in anesthetized micro miniature pigs, not patients.

Preliminary appraisal framework

Not reported in this record.

Preliminary risk-of-bias status

Not reported in this record.

Appraisal rationale

Not reported in this record.

No single-study GRADE certainty rating is assigned. Certainty is assessed by important outcome across a complete eligible evidence set, not by attaching a final grade to one source.

Provenance

Sources and record status

Identifiers

PMID: 33029275 · DOI: 10.14740/jocmr4267

Publisher access

Open-access full text is available through PMC.

Extraction basis

Open-access PMC full text and PubMed record.

Record revision

2026-08-10