Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

Prenatal Molecular Hydrogen Administration Ameliorates Several Findings in Nitrofen-Induced Congenital Diaphragmatic Hernia

Miura M, Imai K, Tsuda H, Miki R, Tano S, Ito Y, Hirako-Takamura S, Moriyama Y, Ushida T, Iitani Y, Nakano-Kobayashi T, Toyokuni S, Kajiyama H, Kotani T. · International journal of molecular sciences. 2021;22(17):9500.

PreclinicalH₂-rich waterPublished 2021Full text reviewed
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

Source data warningThe source's approximately 0.6 ppm and greater than 0.4 mM descriptions are not mutually equivalent. The number of control dams and handling of within-litter correlations need clarification.
Evidence type

Preclinical

Population or model

Pregnant Sprague–Dawley rats and their offspring with nitrofen-induced congenital diaphragmatic hernia.

Intervention and dose

Pregnant rats received nitrofen on embryonic day 9, then hydrogen-rich drinking water from day 10 until cesarean delivery on day 21. The paper gives both approximately 0.6 ppm and greater than 0.4 mM for the water, which are not equivalent concentrations and require clarification. Water was offered ad libitum, with reported intake around 120 mL/kg/day and replacement every 24 hours. The 100 mg nitrofen dose induced the disease model; it was not a hydrogen dose.

Duration

Embryonic days 10–21; lung and blood-gas assessments immediately around birth, including blood gases five minutes after delivery.

Reported result

Maternal hydrogen water did not reduce diaphragmatic-hernia incidence or restore the lung/body-weight ratio. Offspring with hernia showed improvements in selected immediate blood-gas, lung-structure and oxidative-stress measurements, but oxygen and carbon dioxide values did not fully normalize. Several molecular measures, including surfactant B/C and PDGFRβ, did not improve. Pulmonary arterial pressure, longer-term survival and benefit in human pregnancy were not established.

Main limitation

This chemical teratogen model and immediate newborn measurements cannot establish effects in human congenital diaphragmatic hernia. Analyses selected affected offspring, excluded the two highest and lowest lung/body-weight values in each group, and did not clearly account for litter clustering. Sample sizes vary by assay, hydrogen concentration is inconsistently reported, and long-term survival and direct pulmonary pressure were not measured.

Evidence and classification

What kind of evidence is this?

Evidence type

Preclinical

Reported design

Maternal drinking-water intervention in a nitrofen-induced rat model of congenital diaphragmatic hernia, followed by fetal/neonatal lung assessment.

Research topic

Respiratory health

Administration form

H₂-rich water

Information not yet classified

Some editorial classification fields are still pending. The source-reported outcomes and result are shown below; Hydrogenology does not infer a positive or negative signal from prose automatically.

Reported in the source

Methods

Population or model

Pregnant Sprague–Dawley rats and their offspring with nitrofen-induced congenital diaphragmatic hernia.

Sample

The incidence analysis reports 14 nitrofen-treated and 17 nitrofen-plus-hydrogen-water dams; the control dam count is not clearly specified. Offspring counts vary by assay: lung/body-weight ratio 63/40/76, blood gases 25/26/43, histology 12/13/11, arterial measurements 13 per group and PCR 6 per group. These offspring are clustered within litters and cannot be summed as independent animals.

Duration

Embryonic days 10–21; lung and blood-gas assessments immediately around birth, including blood gases five minutes after delivery.

Intervention

Pregnant rats received nitrofen on embryonic day 9, then hydrogen-rich drinking water from day 10 until cesarean delivery on day 21.

Hydrogen form

Hydrogen gas dissolved in maternal drinking water.

Dose or H₂ specification

The paper gives both approximately 0.6 ppm and greater than 0.4 mM for the water, which are not equivalent concentrations and require clarification. Water was offered ad libitum, with reported intake around 120 mL/kg/day and replacement every 24 hours. The 100 mg nitrofen dose induced the disease model; it was not a hydrogen dose.

Comparator

Untreated control offspring, nitrofen-induced hernia without hydrogen water, and nitrofen-induced hernia with maternal hydrogen water.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Hernia incidence, lung/body-weight ratio, neonatal blood gases, lung airspace and pulmonary arterial wall thickness, oxidative-damage staining, and selected surfactant and vascular-development transcripts.

Reported result

Maternal hydrogen water did not reduce diaphragmatic-hernia incidence or restore the lung/body-weight ratio. Offspring with hernia showed improvements in selected immediate blood-gas, lung-structure and oxidative-stress measurements, but oxygen and carbon dioxide values did not fully normalize. Several molecular measures, including surfactant B/C and PDGFRβ, did not improve. Pulmonary arterial pressure, longer-term survival and benefit in human pregnancy were not established.

Extraction completeness

Full-text editorial synthesis completed for specified fields; qualifications are retained.

Reported adverse events

Systematic maternal and fetal safety was not assessed. The authors cited the model's high lethality as a reason pulmonary arterial pressure could not be measured.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

This chemical teratogen model and immediate newborn measurements cannot establish effects in human congenital diaphragmatic hernia. Analyses selected affected offspring, excluded the two highest and lowest lung/body-weight values in each group, and did not clearly account for litter clustering. Sample sizes vary by assay, hydrogen concentration is inconsistently reported, and long-term survival and direct pulmonary pressure were not measured. These preclinical findings do not establish efficacy or safety in people.

Applies directly to

Pregnant Sprague–Dawley rats and their offspring with nitrofen-induced congenital diaphragmatic hernia. Not directly applicable to patients.

Funding and support

Supported by JSPS grants 17K11227 and 17K11230. The authors declared no potential conflicts and stated that funders had no role in the study.

Conflicts of interest

Supported by JSPS grants 17K11227 and 17K11230. The authors declared no potential conflicts and stated that funders had no role in the study.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

PMID: 34502408 · DOI: 10.3390/ijms22179500

Publisher access

A free full article is available through PubMed Central.

Editorial verification

AI-assisted editorial review of the original full-text methods, results, limitations and disclosures for the specified replacement fields; not independent clinical or statistical validation.

Extraction basis

Primary full-text Methods, Results, table/figure captions, Discussion and disclosures reviewed; AI-assisted editorial review, not clinical validation.

Last reviewed

11 November 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy