Pharmacokinetics of hydrogen after ingesting a hydrogen-rich solution: A study in pigs
Ichihara G, Katsumata Y, Moriyama H, Kitakata H, Hirai A, Momoi M, Ko S, Shinya Y, Kinouchi K, Kobayashi E, Sano M. · Heliyon. 2021;7(11):e08359.
Study at a glance
Preclinical
Four anesthetized8-week-old female pigs, without an induced disease model.
500 mL glucose solution delivered directly into the small intestine through a surgically placed tube over2 minutes. Measured5.42 mg/L hydrogen; glucose1.5g/kg in500 mL solution. Reported blood percentages represent saturation relative to 1.6 mg/L, not inhaled gas concentration.
Single infusion, vascular blood sampling over120 minutes.
In the2hydrogen-exposed pigs, hydrogen rose rapidly in intestinal and portal venous blood and remained detectable over the2-hour observation period. Concentrations were lower after passage through the liver, while carotid concentrations were undetectable or extremely low. Table 1 shows tiny arterial readings in one pig despite prose saying none was detected. The experiment did not measure treatment benefit and cannot establish human drinking-water kinetics or that hydrogen never reaches systemic circulation.
Only2treated animals and 1fully confirmed control, with direct jejunal infusion rather than ordinary drinking.
What kind of evidence is this?
Preclinical
Small descriptive pig pharmacokinetic experiment with vascular catheter sampling after direct intestinal administration.
Other molecular hydrogen research
Other forms
Information not yet classified
Some editorial classification fields are still pending. The source-reported outcomes and result are shown below; Hydrogenology does not infer a positive or negative signal from prose automatically.
Methods
Four anesthetized8-week-old female pigs, without an induced disease model.
4pigs:2hydrogen solution and 2hydrogen-free controls. One control had incorrectly positioned jejunal catheter, leaving1confirmed control for relevant comparison; duplicate laboratory measurements are not additional animals.
Single infusion, vascular blood sampling over120 minutes.
500 mL glucose solution delivered directly into the small intestine through a surgically placed tube over2 minutes.
Dissolved hydrogen in glucose solution administered enterally beyond the stomach.
Measured5.42 mg/L hydrogen; glucose1.5g/kg in500 mL solution. Reported blood percentages represent saturation relative to 1.6 mg/L, not inhaled gas concentration.
Hydrogen-free glucose solution and pre-infusion blood measurements.
Outcomes and reported result
Hydrogen concentrations in jejunal/portal veins, suprahepatic inferior vena cava and carotid artery; glucose checked catheter placement.
In the2hydrogen-exposed pigs, hydrogen rose rapidly in intestinal and portal venous blood and remained detectable over the2-hour observation period. Concentrations were lower after passage through the liver, while carotid concentrations were undetectable or extremely low. Table 1 shows tiny arterial readings in one pig despite prose saying none was detected. The experiment did not measure treatment benefit and cannot establish human drinking-water kinetics or that hydrogen never reaches systemic circulation.
Full-text editorial synthesis; unresolved reporting details are stated explicitly.
No systematic clinical safety outcomes; this was an invasive anesthetized-animal measurement experiment.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Descriptive results without a powered randomized comparison. Surgery, anesthesia, glucose and 48-hour milk feeding may affect absorption. Tissue effects and elimination pathways were inferred, not directly quantified as a complete hydrogen mass balance.
Hydrogen distribution after this direct jejunal infusion in pigs, not proven efficacy or dosing guidance for human hydrogen water.
Doctors Man Co., Ltd. funded the work and supplied the filling device. M.Sano and E.Kobayashi disclosed advisory fees and inventorship of a joint hydrogen organ-preservation patent. Funder stated to have no design/analysis/publication role.
Doctors Man Co., Ltd. funded the work and supplied the filling device. M.Sano and E.Kobayashi disclosed advisory fees and inventorship of a joint hydrogen organ-preservation patent. Funder stated to have no design/analysis/publication role.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 34816046 · DOI: 10.1016/j.heliyon.2021.e08359
A free full article is available through PubMed Central.
AI-assisted editorial review of the original full-text methods, results, limitations and disclosures for the specified replacement fields; not independent clinical or statistical validation.
Original full-text methods, results, figures/tables, discussion and disclosures reviewed. AI-assisted editorial extraction; not an independent medical review.
11 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.