Accurate in vivo real-time determination of the hydrogen concentration in different tissues of mice after hydrogen inhalation
Zhu W, Gu Q, Liu B, Si Y, Sun H, Zhong J, Lu Y, Wang D, Xue J, Qin S. · Heliyon. 2022;8(10):e10778.
Study at a glance
Preclinical
Eight-week-old C57BL/6J mice, without an induced disease model; brain, kidney, liver, spleen and gastrocnemius muscle measured.
Continuous inhalation until tissue hydrogen reached a plateau, followed by air until baseline returned. 4%, 42% and 67% hydrogen, measured with a gas detector; tissue concentrations assessed with a calibrated Clark-type microsensor. These are experimental exposures, not clinical dose recommendations.
Acutely during rise to tissue plateau and washout to baseline; no single fixed exposure duration or long-term treatment period.
Hydrogen reached all five sampled tissues, but concentrations and timing differed substantially: kidney and brain reached higher levels quickly, while muscle rose and cleared more slowly. Higher inhaled concentrations generally produced higher tissue concentrations. These distribution measurements do not show therapeutic benefit, penetration of every cell, or one universal time that hydrogen stays in the body.
Invasive measurements in a small number of anesthetized mice, not human pharmacokinetics or an efficacy/safety trial.
What kind of evidence is this?
Preclinical
Physiological exposure/distribution experiment measuring hydrogen directly in exposed tissues of anesthetized mice.
Other molecular hydrogen research
Inhaled H₂
Information not yet classified
Some editorial classification fields are still pending. The source-reported outcomes and result are shown below; Hydrogenology does not infer a positive or negative signal from prose automatically.
Methods
Eight-week-old C57BL/6J mice, without an induced disease model; brain, kidney, liver, spleen and gastrocnemius muscle measured.
25 mice purchased; plotted measurements generally 3–5 mice per tissue. The discussion reports 8 liver measurements but selection of 5 similar curves, without a fully specified exclusion rule.
Acutely during rise to tissue plateau and washout to baseline; no single fixed exposure duration or long-term treatment period.
Continuous inhalation until tissue hydrogen reached a plateau, followed by air until baseline returned.
Hydrogen-containing gas mixtures.
4%, 42% and 67% hydrogen, measured with a gas detector; tissue concentrations assessed with a calibrated Clark-type microsensor. These are experimental exposures, not clinical dose recommendations.
Baseline air exposure, different hydrogen concentrations, different tissues; published rat data used for a secondary species comparison.
Outcomes and reported result
Real-time tissue hydrogen concentration, saturation concentration and washout pattern.
Hydrogen reached all five sampled tissues, but concentrations and timing differed substantially: kidney and brain reached higher levels quickly, while muscle rose and cleared more slowly. Higher inhaled concentrations generally produced higher tissue concentrations. These distribution measurements do not show therapeutic benefit, penetration of every cell, or one universal time that hydrogen stays in the body.
Full-text editorial synthesis; unresolved reporting details are stated explicitly.
No systematic safety outcomes were assessed. Surgery, anesthesia and high-concentration experimental exposures limit transfer to awake humans.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Open-tissue measurements may alter normal physiology and sensor accuracy. Inconsistent selection/retention of curves is acknowledged in the discussion. No lung or blood measurements, no randomized clinical comparison and no direct testing of alternative routes.
Hydrogen distribution in the five measured mouse tissues under these experimental conditions.
National Training Program for Undergraduate Innovation and Entrepreneurship S202010439011 and Shandong First Medical University Academic Promotion Programme 2019QL010. Authors declared no conflict of interest.
National Training Program for Undergraduate Innovation and Entrepreneurship S202010439011 and Shandong First Medical University Academic Promotion Programme 2019QL010. Authors declared no conflict of interest.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 36203896 · DOI: 10.1016/j.heliyon.2022.e10778
A free full article is available through PubMed Central.
AI-assisted editorial review of the original full-text methods, results, limitations and disclosures for the specified replacement fields; not independent clinical or statistical validation.
Original full-text methods, results, figures/tables, discussion and disclosures reviewed. AI-assisted editorial extraction; not an independent medical review.
11 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.