Spatiotemporal Co-Delivery of Hydrogen and Magnesium via Microneedle Patches for Neuroinflammation Modulation After Spinal Cord Injury: A Multi-Modal In Vivo Study.
Wang H, Sun Y, Wang S, Wang W, Tang J, Li Z, Jiang X, Zhou L, Wu J, Guo Q, Zhu Y, Feng Y, Xi K, Chen L. · Small. 2026;22(21):e14854.
Study at a glance
A magnesium-containing microneedle patch that releases hydrogen was tested in rats with spinal cord injury and in cell experiments. Rats receiving the patch recovered more hindlimb movement over eight weeks than untreated injured rats, with changes in inflammation and tissue-repair markers. This was not a human trial, and the treatment combined hydrogen, magnesium and an implanted material. Important reporting problems include inconsistent animal numbers and mechanical measurements, and a macrophage cell line described as microglia. The supplementary file could not be verified. The results should therefore be treated as preliminary evidence about an experimental patch, not proof that hydrogen alone repairs spinal cord injury.
Preclinical
Female Sprague–Dawley rats with spinal cord injury, primary rat neural stem cells and RAW264.7 macrophages; no human participants.
5% w/v HAMA microneedles made from 600 microlitres precursor/mold, with Mg powder approximately 40 micrometres sedimented toward needle tips; 10x10 needles, approximately 600 micrometres high. Patches implanted at exposed injured T9 spinal cord following vascular-clip compression for 8 seconds. Absolute Mg mass per implanted patch and measured in-vivo H2 dose are not clearly specified. Release assay compared 3 mg Mg powder or 5 patches in 10 mL water; the paper reports cumulative release 84.6±1.04 micromol H2 and 11.60±0.04 mg Mg2+ over 7 days for patch material, with assay conditions/units not fully consistent across sections. Do not present these bench values as a rat or human administered gas dose. · 5% w/v HAMA microneedles made from 600 microlitres precursor/mold, with Mg powder approximately 40 micrometres sedimented toward needle tips; 10x10 needles, approximately 600 micrometres high. Patches implanted at exposed injured T9 spinal cord following vascular-clip compression for 8 seconds. Absolute Mg mass per implanted patch and measured in-vivo H2 dose are not clearly specified. Release assay compared 3 mg Mg powder or 5 patches in 10 mL water; the paper reports cumulative release 84.6±1.04 micromol H2 and 11.60±0.04 mg Mg2+ over 7 days for patch material, with assay conditions/units not fully consistent across sections. Do not present these bench values as a rat or human administered gas dose.
Motor recovery followed weekly for 8 weeks; tissue assessments at days 3/7 and weeks 4/8; material release over 7 days; separate subcutaneous compatibility assessment at 14 days.
At 8 weeks the reported BBB score was 14.8±1.17 for Mg patches versus 5.5±1.05 for untreated SCI and 5.8±1.32 for HAMA-only patches. Recovery was incomplete and the model was a rat injury experiment. The inclined-plane result for Mg patches was 59.17±3.76 degrees. The material was associated with lower ROS/inflammatory signals and greater neuronal, axonal and vascular staining; AP1 agonist experiments attenuated selected effects. ERK phosphorylation was not significantly changed, so generalized inhibition of every MAPK branch is unsupported. HAMA-only treatment did not significantly improve several locomotor/inflammatory/stem-cell-homing outcomes over SCI alone. Cell proliferation was not uniformly improved: some early comparisons were null, and control proliferation exceeded Mg groups at day 5.
Main text repeatedly calls RAW264.7 cells microglia, although methods identify a macrophage line; staining for Iba1/CD11b does not correct that identity problem.
What kind of evidence is this?
Preclinical
Experimental HAMA hydrogel microneedle patches co-delivering hydrogen and magnesium; primary rat neural stem cells, RAW264.7 macrophages and a rat T9 compression spinal-cord-injury model.
Other neurological conditions
Other forms
Mixed preclinical findings and reporting contradictions
BBB locomotor score, inclined-plane/footprint tests, cavity/scar histology, oxidative/inflammatory markers, axonal/neuronal/vascular markers, transcriptomics and proposed JNK/p38–AP1 signalling.
Methods
Female Sprague–Dawley rats with spinal cord injury, primary rat neural stem cells and RAW264.7 macrophages; no human participants.
Female Sprague–Dawley rats, 6–8 weeks, approximately 220 g. Main setup states five groups n=6/group; histology methods separately state ten rats/group allocated to 4- and 8-week endpoints. These counts are unresolved; do not sum them or state a unique overall N. Transcriptomics n=3/group; many tissue/cell figures n=3. In-vitro neural stem cells derived from E14 rat fetal brains; RAW264.7 is a murine macrophage line, not primary microglia.
Motor recovery followed weekly for 8 weeks; tissue assessments at days 3/7 and weeks 4/8; material release over 7 days; separate subcutaneous compatibility assessment at 14 days.
5% w/v HAMA microneedles made from 600 microlitres precursor/mold, with Mg powder approximately 40 micrometres sedimented toward needle tips; 10x10 needles, approximately 600 micrometres high. Patches implanted at exposed injured T9 spinal cord following vascular-clip compression for 8 seconds. Absolute Mg mass per implanted patch and measured in-vivo H2 dose are not clearly specified. Release assay compared 3 mg Mg powder or 5 patches in 10 mL water; the paper reports cumulative release 84.6±1.04 micromol H2 and 11.60±0.04 mg Mg2+ over 7 days for patch material, with assay conditions/units not fully consistent across sections. Do not present these bench values as a rat or human administered gas dose.
Implanted magnesium-containing hydrogen-generating microneedle patch.
5% w/v HAMA microneedles made from 600 microlitres precursor/mold, with Mg powder approximately 40 micrometres sedimented toward needle tips; 10x10 needles, approximately 600 micrometres high. Patches implanted at exposed injured T9 spinal cord following vascular-clip compression for 8 seconds. Absolute Mg mass per implanted patch and measured in-vivo H2 dose are not clearly specified. Release assay compared 3 mg Mg powder or 5 patches in 10 mL water; the paper reports cumulative release 84.6±1.04 micromol H2 and 11.60±0.04 mg Mg2+ over 7 days for patch material, with assay conditions/units not fully consistent across sections. Do not present these bench values as a rat or human administered gas dose.
Sham laminectomy; SCI without patch; HAMA-only patch; MgCl2-loaded HAMA; Mg-loaded HAMA. Mechanistic cell experiments add AP1 agonist 15(S)-HPETE.
Outcomes and reported result
BBB locomotor score, inclined-plane/footprint tests, cavity/scar histology, oxidative/inflammatory markers, axonal/neuronal/vascular markers, transcriptomics and proposed JNK/p38–AP1 signalling.
At 8 weeks the reported BBB score was 14.8±1.17 for Mg patches versus 5.5±1.05 for untreated SCI and 5.8±1.32 for HAMA-only patches. Recovery was incomplete and the model was a rat injury experiment. The inclined-plane result for Mg patches was 59.17±3.76 degrees. The material was associated with lower ROS/inflammatory signals and greater neuronal, axonal and vascular staining; AP1 agonist experiments attenuated selected effects. ERK phosphorylation was not significantly changed, so generalized inhibition of every MAPK branch is unsupported. HAMA-only treatment did not significantly improve several locomotor/inflammatory/stem-cell-homing outcomes over SCI alone. Cell proliferation was not uniformly improved: some early comparisons were null, and control proliferation exceeded Mg groups at day 5.
Published complete main text reviewed; supplementary PDF could not be accessed as a valid PDF. Supplementary PDF could not be accessed as a valid PDF; no complete supplementary verification is claimed. Null findings, source inconsistencies and unreported values are retained; no independent reanalysis.
Short cell tests and local/subcutaneous histology were reported as compatible, but some live-cell fluorescence/proliferation comparisons were lower than controls. No complete long-term neurological/systemic implant safety assessment or human adverse-event dataset.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Main text repeatedly calls RAW264.7 cells microglia, although methods identify a macrophage line; staining for Iba1/CD11b does not correct that identity problem. Animal n=6 versus n=10/group is inconsistent. Dura thickness is reported as approximately 420±35 micrometres in one experiment and 150±42 micrometres elsewhere; mechanical-modulus descriptions also conflict (400 MPa dry/40 kPa wet versus approximately 1 MPa in discussion). Precise safe penetration/mechanical matching cannot be treated as settled. Supplementary material was unavailable through the legitimate source attempts; supporting-only claims cannot be independently confirmed. H2 and Mg ions co-release, and material properties/pH differ; MgCl2 is not a complete matched H2-only or equal-kinetics magnesium control. The independent contribution of H2 is not established. No humans treated; 8-week small rodent work cannot establish long-term implant safety, clinical regeneration or efficacy of consumer hydrogen devices.
The reported population or experimental model and protocol only; clinical benefit and general safety are not established.
NSFC 82120108017, 82272501, 82572769, 82372484, 82302683; Jiangsu Project 333 (2069999), BK20250123/BK20230215; China Postdoctoral Science Foundation 2025M782215; Suzhou SSD2025025, GSWS2023093; Soochow ML12202923; Tongji Ministry of Education laboratory BZ2024003; Jiangsu PAPD.
Authors declare no conflict of interest.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 41693370 · DOI: 10.1002/smll.202514854
Published main full text available through the linked original source.
No correction, retraction or expression-of-concern notice identified in supplied full text/metadata or targeted DOI searches on 24 November 2026. Limited notice screen, not an integrity certification.
Editorial integration of the supplied source review; not independent medical or statistical validation.
Complete main XML including all methods, figures/captions, limitations, funding and ethics read. Main-text quantitative results extracted as reported; supplement access failure preserved explicitly. No claim of complete supplementary verification. Supplementary scope: Supplementary PDF could not be accessed as a valid PDF; no complete supplementary verification is claimed.
Complete published main full-text article reviewed using the supplied study-specific review packet. Supplementary scope is stated separately; no independent clinical, statistical or image-forensic validation.
Ethics and consent reporting: Animal committee approval IACUC-2022095048; methods name Xuzhou Medical University Ethics Committee. Related-data limitations: No explicit reused participant cohort or animal dataset was identified in the reviewed comparisons. This does not establish independence of every laboratory dataset.
24 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 761 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.