Languages

Read Hydrogenology in your language

Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

Safety and Influence of Molecular Hydrogen/Carbon Dioxide Contained Drinking Water on Common Anthropometric and Laboratory Parameters.

Ikeda Y, Muroya S, Satou K, Inoue G, Koike K, Maekawa T. · Yamaguchi Medical Journal 70(3):109–118

HumanH₂-rich waterPublished 2021Entire 10-page original PDF read, including Japanese main text, Figure 1, Tables 1A/1B/2A/2B/3A/3B/4, disclosures, references and English summary. Embedded tables visually read from rendered pages 4–7. J-STAGE explicitly lists zero electronic supplements; no unreviewed supplement is claimed.
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

In this Japanese crossover study, 39 healthy hospital volunteers completed both water regimens: one litre daily of carbonated water and the same water with added hydrogen. Each regimen was planned for 31 drinking days, with at least 31 days between them. Hydrogen measured about 0.5 ppm in the drinking mug. Blood pressure fell during the hydrogen period, but the fall was not statistically different from that during ordinary carbonated-water treatment. Most comparisons between regimens, including blood oxygen saturation, breath hydrogen and routine blood tests, were also negative. Small increases in pulse and bilirubin differed between treatments; bilirubin remained within expected physiological variation. No particular adverse events were reported. The small completer-only study, many statistical tests and unreported randomization mean that it offers limited short-term tolerability information rather than proof of a health benefit.

Source data warningControlled blood-pressure differences were NULL (systolic P=.1086; diastolic P=.1627). Consumed mug water contained approximately 0.5 ppm H₂, not the server’s 2.0 ppm. Small pulse/bilirubin changes do not establish clinical benefit; Iwatani industry involvement is disclosed.
Evidence type

Human

Population or model

Healthy hospital-staff volunteers completing two carbonated-water regimens; 39 analyzed participants.

Intervention and dose

1000 mL/day of water containing H2 plus CO2, for 31 drinking days within an allowed 45-day period. Server H2 2.0 ppm and CO2 1000 ppm, but H2 in the drinking mug was approximately 0.5 ppm (about 0.5 mg/L, nominally about 0.5 mg/day). Do not use the 2.0 ppm server concentration as the consumed dose. · 1000 mL/day of water containing H2 plus CO2, for 31 drinking days within an allowed 45-day period. Server H2 2.0 ppm and CO2 1000 ppm, but H2 in the drinking mug was approximately 0.5 ppm (about 0.5 mg/L, nominally about 0.5 mg/day). Do not use the 2.0 ppm server concentration as the consumed dose.

Duration

Each regimen prescribed 31 drinking days within a 45-day window, separated by at least 31 days; analyses required at least 26 days per regimen. The English abstract abbreviates this as 26 days, while detailed methods and Figure 1 specify the adherence rule.

Reported result

Within the H2/CO2 period, mean systolic pressure fell 5.2 mmHg (P=.0083) and diastolic pressure fell 2.8 mmHg (P=.0066). However, the CONTROLLED differences in changes versus CO2 water were not significant: −4.1 mmHg systolic, P=.1086; −1.5 mmHg diastolic, P=.1627. This study does not establish an H2-specific blood-pressure benefit. Between-regimen differences in change were statistically significant only for pulse (+3.4 beats/min, P=.0499) and total bilirubin (+0.13 mg/dL, P=.0286). The bilirubin change was within the reported 90% reference-change value (0.35 mg/dL). The pulse difference was small; no symptom or clinical benefit was demonstrated. End-expiratory H2 rose by 2.4 ppm during H2/CO2 treatment but was nonsignificant (Table 1B P=.0647); the between-regimen H2 change was also nonsignificant (+2.5 ppm, P=.1417). SpO2 rose 0.43 percentage points in the CO2-only period (P=.0273), not significantly more with H2 (between-regimen difference −0.27 points, P=.1963). Several within-period blood tests changed in each water regimen. Reported changes remained within physiological reference-change ranges and do not show clinical organ protection. Between-regimen CRP, AST, gamma-GTP, cholinesterase, CK, CK-MB, renal markers, electrolytes and cell-count outcomes were nonsignificant; platelet P=.0540 is not a positive result.

Main limitation

39 analyzed volunteers and adherence/outlier exclusions; possible selection and attrition bias.

Evidence and classification

What kind of evidence is this?

Evidence type

Human

Reported design

Two-period crossover; equal initial allocation and participant masking are described, but random sequence generation, concealed allocation and assessor masking are not reported. Pre/post and paired difference-in-change Wilcoxon tests, P<.05, with 90% reference change values for clinical laboratory interpretation.

Original-language title

水素/炭酸ガス含有飲用水の各種生体計測値への影響と安全性の検討

Research topic

Other molecular hydrogen research

Administration form

H₂-rich water

Study result signal

Controlled BP comparison null; small exploratory laboratory differences

Outcome type

Blood pressure, pulse, oxygen saturation, end-expiratory H2, routine clinical chemistry, electrolytes and blood-cell counts before and near the end of each period.

Reported in the source

Methods

Population or model

Healthy hospital-staff volunteers completing two carbonated-water regimens; 39 analyzed participants.

Sample

Hospital-staff volunteers aged 20–69 years; 50 was the planned/targeted sample, five men and five women in each decade. Analysis retained 39 participants drinking on at least 26 of 31 planned days in BOTH periods. Outcome-specific changes at least 3 SD from the mean were excluded (0–2 people per measure). No intention-to-treat result is supplied.

Duration

Each regimen prescribed 31 drinking days within a 45-day window, separated by at least 31 days; analyses required at least 26 days per regimen. The English abstract abbreviates this as 26 days, while detailed methods and Figure 1 specify the adherence rule.

Intervention

1000 mL/day of water containing H2 plus CO2, for 31 drinking days within an allowed 45-day period. Server H2 2.0 ppm and CO2 1000 ppm, but H2 in the drinking mug was approximately 0.5 ppm (about 0.5 mg/L, nominally about 0.5 mg/day). Do not use the 2.0 ppm server concentration as the consumed dose.

Hydrogen form

Oral hydrogen-added carbonated water versus carbonated water without added hydrogen.

Dose or H₂ specification

1000 mL/day of water containing H2 plus CO2, for 31 drinking days within an allowed 45-day period. Server H2 2.0 ppm and CO2 1000 ppm, but H2 in the drinking mug was approximately 0.5 ppm (about 0.5 mg/L, nominally about 0.5 mg/day). Do not use the 2.0 ppm server concentration as the consumed dose.

Comparator

Carbonated water containing CO2 1000 ppm without added H2; the same people crossed over after at least 31 days of washout. No plain-water arm. CO2 was present in BOTH regimens.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Blood pressure, pulse, oxygen saturation, end-expiratory H2, routine clinical chemistry, electrolytes and blood-cell counts before and near the end of each period.

Reported result

Within the H2/CO2 period, mean systolic pressure fell 5.2 mmHg (P=.0083) and diastolic pressure fell 2.8 mmHg (P=.0066). However, the CONTROLLED differences in changes versus CO2 water were not significant: −4.1 mmHg systolic, P=.1086; −1.5 mmHg diastolic, P=.1627. This study does not establish an H2-specific blood-pressure benefit. Between-regimen differences in change were statistically significant only for pulse (+3.4 beats/min, P=.0499) and total bilirubin (+0.13 mg/dL, P=.0286). The bilirubin change was within the reported 90% reference-change value (0.35 mg/dL). The pulse difference was small; no symptom or clinical benefit was demonstrated. End-expiratory H2 rose by 2.4 ppm during H2/CO2 treatment but was nonsignificant (Table 1B P=.0647); the between-regimen H2 change was also nonsignificant (+2.5 ppm, P=.1417). SpO2 rose 0.43 percentage points in the CO2-only period (P=.0273), not significantly more with H2 (between-regimen difference −0.27 points, P=.1963). Several within-period blood tests changed in each water regimen. Reported changes remained within physiological reference-change ranges and do not show clinical organ protection. Between-regimen CRP, AST, gamma-GTP, cholinesterase, CK, CK-MB, renal markers, electrolytes and cell-count outcomes were nonsignificant; platelet P=.0540 is not a positive result.

Extraction completeness

Entire 10-page original PDF read, including Japanese main text, Figure 1, Tables 1A/1B/2A/2B/3A/3B/4, disclosures, references and English summary. Embedded tables visually read from rendered pages 4–7. J-STAGE explicitly lists zero electronic supplements; no unreviewed supplement is claimed. J-STAGE lists zero electronic supplements. Nulls, limitations and unresolved reporting are retained; no independent reanalysis.

Reported adverse events

Authors report no particular adverse events and interpret laboratory shifts as within physiological variability. This is short, small, completer-only observation in healthy volunteers; it does not establish universal or long-term safety. Structured symptom-frequency tables were not provided.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

39 analyzed volunteers and adherence/outlier exclusions; possible selection and attrition bias. Multiple outcomes and marginal P=.0499/.0286 without multiplicity correction; no reported period/carryover model or prospective power calculation. Within-period BP changes should not replace null controlled comparisons. Industry-built server and two Iwatani R&D coauthors; both regimens carbonated, no plain-water arm. Consumed H2 concentration was approximately one quarter of server concentration; limited exposure verification and no clinical disease endpoint.

Applies directly to

The stated population or experimental model and protocol only; clinical benefit and general safety are not established.

Funding and support

Yamaguchi Prefecture fiscal 2014 industrial strategic R&D subsidy, project on development of hydrogen application technology in medical and health fields.

Conflicts of interest

Authors declare no reportable conflicts. Inoue and Koike are affiliated with Iwatani Corporation R&D, which made the water servers; retain this disclosed industry involvement.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

DOI: 10.2342/ymj.70.109 · DOI: 10.2342/ymj.70.109

Publisher access

Published main full text available through the linked original source.

Publication status

No correction, retraction or expression of concern found in original text and targeted DOI notice searches on 24 November 2026. Limited check, not a guarantee.

Editorial verification

Editorial integration of the supplied source review, not independent medical or statistical validation.

Source sections checked

Entire 10-page original PDF read, including Japanese main text, Figure 1, Tables 1A/1B/2A/2B/3A/3B/4, disclosures, references and English summary. Embedded tables visually read from rendered pages 4–7. J-STAGE explicitly lists zero electronic supplements; no unreviewed supplement is claimed. Supplementary scope: J-STAGE lists zero electronic supplements.

Extraction basis

Complete original main full-text article reviewed in the supplied source-specific packet. Supplementary review scope is stated separately; no independent medical, statistical or image-forensic validation.

Registry / related-source limitations

Ethics and consent: Yamaguchi Prefectural General Medical Center clinical-trial/ethics committee approval 2015-008; written informed consent; Declaration of Helsinki. Related-data limitations: The preliminary presentation at the seventh Japanese molecular hydrogen medical/biological meeting in Nagoya, 2017, is not an additional independent cohort. No reused volunteer dataset was identified; individual-level linkage was not available.

Last reviewed

24 November 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 761 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy

Send the exact difference between this page and the linked source. The study reference is attached automatically.