Controlled Release of Hydrogen-Carrying Perfluorocarbons for Ischemia Myocardium-Targeting 19F MRI-Guided Reperfusion Injury Therapy.
Nie C, A R, Wang J, Pan S, Zou R, Wang B, Xi S, Hong X, Zhou M, Wang H, Yu M, Wu L, Sun X, Yang W. · Advanced Science. 2023.
Study at a glance
Researchers developed an injectable carrier that held more hydrogen than water and accumulated in injured mouse heart tissue. In mice whose coronary artery had been temporarily blocked, the carrier was associated with less heart damage and better later heart-function measurements. Focused ultrasound triggered faster release and strengthened several effects. These findings concern an experimental injection and ultrasound procedure, not drinking hydrogen water or using a home inhaler. The report has unclear wording for some acute heart-function percentages, and its supplementary file was not accessible for this review. Human benefit and safety remain unestablished.
Preclinical
Mouse myocardial ischemia–reperfusion models and primary-cell experiments; no human participants.
Tail-vein H₂-loaded perfluorooctylbromide nanoemulsion, 30%v/v PFOB at 10 µL/g body weight, given at reperfusion after 60 min coronary occlusion. Measured hydrogen loading approximately 6 mM. Optional low-intensity focused ultrasound immediately afterward for 20 min:1.1 MHz, 55.8 mW/cm², 50%duty cycle, 0.4 cm² focus. H₂-water comparator was also injected intravenously—not drunk. · 30% v/v perfluorooctylbromide nanoemulsion at 10 μL/g body weight after 60 minutes of coronary occlusion; hydrogen loading around 6 mM. Optional ultrasound: 1.1 MHz, 55.8 mW/cm², 50% duty cycle, 0.4 cm² focus, for 20 minutes. This was not drinking water or inhalation.
Acute reperfusion endpoints plus 28 day follow-up. Carrier fluorescence distribution assessed to 72 h; this describes carrier kinetics, not a measured 72 h lifetime of free hydrogen.
The nanoemulsion held about 6 mM hydrogen, roughly 8 times the water comparator; ultrasound accelerated release. In this model, uptake was enriched in injured myocardium and in inflammatory monocyte/macrophage populations. Authors report smaller infarct fractions, lower injury/oxidative/pyroptosis markers and better cardiac outcomes with H₂-PFOB, particularly plus ultrasound, compared with their water and carrier controls. Area-at-risk/left-ventricle ratio did not differ significantly. At 28 days the text gives ejection-fraction values 57.4%, 54.7% and 48.8% in the comparison of combination, nanoemulsion and water groups. Acute EF/FS prose ambiguously describes decreases and percentages in an order inconsistent with the stated improvement; avoid republishing those acute percentages as verified absolute EF/FS. Survival is presented graphically; no precise mortality effect independently extracted. No obvious cell toxicity, organ histological lesions or significant measured liver/kidney/hematology changes were reported in limited short-term safety assays. This does not establish human intravenous safety.
Animal/cell nanomaterial study, not an inhalation or oral-water trial in patients.
What kind of evidence is this?
Preclinical
Balb/c mouse coronary-occlusion/reperfusion study with imaging, mechanistic and 28 day outcome experiments; complementary primary-cell tests. Echocardiography was performed by an operator blinded to assignment. Overall randomization and total unique-animal count were not fully described.
Cardiovascular and circulatory health
Other forms
Mixed preclinical findings
H₂ storage/release, myocardial uptake, 19 F-MRI signal, infarct-area/area-at-risk ratio, troponin/LDH, echocardiography, FDG-PET, oxidative-stress and pyroptosis markers, survival curves, fibrosis and short-term biochemistry/histology.
Methods
Mouse myocardial ischemia–reperfusion models and primary-cell experiments; no human participants.
Balb/c mice 22–25 g. Acute infarct/serum endpoints n=7/group, acute echocardiography n=15/group, fluorescence/MRI/flow/protein assays typically n=5, 28 day cardiac structure n=7, several fibrosis/BNP endpoints n=5. These are separate endpoint counts and cannot be summed to infer a verified unique-animal total. Sex not specified in main animal section.
Acute reperfusion endpoints plus 28 day follow-up. Carrier fluorescence distribution assessed to 72 h; this describes carrier kinetics, not a measured 72 h lifetime of free hydrogen.
Tail-vein H₂-loaded perfluorooctylbromide nanoemulsion, 30%v/v PFOB at 10 µL/g body weight, given at reperfusion after 60 min coronary occlusion. Measured hydrogen loading approximately 6 mM. Optional low-intensity focused ultrasound immediately afterward for 20 min:1.1 MHz, 55.8 mW/cm², 50%duty cycle, 0.4 cm² focus. H₂-water comparator was also injected intravenously—not drunk.
Intravenous hydrogen-loaded perfluorocarbon nanoemulsion, with optional focused ultrasound. The hydrogen-water comparator was also intravenous.
30% v/v perfluorooctylbromide nanoemulsion at 10 μL/g body weight after 60 minutes of coronary occlusion; hydrogen loading around 6 mM. Optional ultrasound: 1.1 MHz, 55.8 mW/cm², 50% duty cycle, 0.4 cm² focus, for 20 minutes. This was not drinking water or inhalation.
Sham and ischemia–reperfusion controls; non-hydrogenated PFOB; intravenously administered H₂-water; H₂-PFOB with or without ultrasound, as shown in respective experimental figures. Endpoint groups vary; do not claim all assays had the same n.
Outcomes and reported result
H₂ storage/release, myocardial uptake, 19 F-MRI signal, infarct-area/area-at-risk ratio, troponin/LDH, echocardiography, FDG-PET, oxidative-stress and pyroptosis markers, survival curves, fibrosis and short-term biochemistry/histology.
The nanoemulsion held about 6 mM hydrogen, roughly 8 times the water comparator; ultrasound accelerated release. In this model, uptake was enriched in injured myocardium and in inflammatory monocyte/macrophage populations. Authors report smaller infarct fractions, lower injury/oxidative/pyroptosis markers and better cardiac outcomes with H₂-PFOB, particularly plus ultrasound, compared with their water and carrier controls. Area-at-risk/left-ventricle ratio did not differ significantly. At 28 days the text gives ejection-fraction values 57.4%, 54.7% and 48.8% in the comparison of combination, nanoemulsion and water groups. Acute EF/FS prose ambiguously describes decreases and percentages in an order inconsistent with the stated improvement; avoid republishing those acute percentages as verified absolute EF/FS. Survival is presented graphically; no precise mortality effect independently extracted. No obvious cell toxicity, organ histological lesions or significant measured liver/kidney/hematology changes were reported in limited short-term safety assays. This does not establish human intravenous safety.
Published main text reviewed; supplementary PDF access not confirmed. Supplementary-only details were not independently checked. Acute cardiac-percentage ambiguities remain explicit.
Selected short-term safety observations are reported in Results; no comprehensive clinical safety assessment was performed.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Animal/cell nanomaterial study, not an inhalation or oral-water trial in patients. Delivery carrier, ultrasound and hydrogen loading differ across groups; enhanced delivery cannot be assumed for consumer devices. Exact total unique animals, allocation/attrition and several methods are incomplete. Acute EF/FS numerical wording is internally unclear. Supporting PDF could not be retrieved through PMC/publisher routes at this review. Do not label supplements reviewed; supplementary-only safety and cell details remain author-reported in the main text. No independent raw-data reanalysis, formal image forensics or proof of clinical efficacy.
The population or experimental model and protocol described here; clinical benefit and general safety are not established.
NSFC 81871459; Heilongjiang Tou-Yan Innovation Team 2019-15; Fourth Affiliated Hospital of Harbin Medical UniversityHYDSYTB 202001; Heilongjiang Key R&D SC 2022 ZX 06 C 0012.
Authors declare no conflict of interest.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 37596718 · DOI: 10.1002/advs.202304178
Published main full text available through the linked original source.
Source verification based on the supplied publication review. This is editorial extraction, not independent medical or statistical validation.
Complete published main text. Supplementary PDF inaccessible; not reviewed.
Complete published main full-text article reviewed. Supplementary review scope is stated separately; no independent medical, statistical or image-forensic validation.
22 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.