Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

Controlled Release of Hydrogen-Carrying Perfluorocarbons for Ischemia Myocardium-Targeting 19F MRI-Guided Reperfusion Injury Therapy.

Nie C, A R, Wang J, Pan S, Zou R, Wang B, Xi S, Hong X, Zhou M, Wang H, Yu M, Wu L, Sun X, Yang W. · Advanced Science. 2023.

PreclinicalOther formsPublished 2023Published main text reviewed; supplementary PDF access not confirmed
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

Researchers developed an injectable carrier that held more hydrogen than water and accumulated in injured mouse heart tissue. In mice whose coronary artery had been temporarily blocked, the carrier was associated with less heart damage and better later heart-function measurements. Focused ultrasound triggered faster release and strengthened several effects. These findings concern an experimental injection and ultrasound procedure, not drinking hydrogen water or using a home inhaler. The report has unclear wording for some acute heart-function percentages, and its supplementary file was not accessible for this review. Human benefit and safety remain unestablished.

Source data warningThe supplementary PDF remained inaccessible and was not reviewed. Some acute EF/FS wording is internally ambiguous; precise acute percentages and mortality effects were not independently extracted. Carrier fluorescence to 72 hours is not the lifetime of free hydrogen.
Evidence type

Preclinical

Population or model

Mouse myocardial ischemia–reperfusion models and primary-cell experiments; no human participants.

Intervention and dose

Tail-vein H₂-loaded perfluorooctylbromide nanoemulsion, 30%v/v PFOB at 10 µL/g body weight, given at reperfusion after 60 min coronary occlusion. Measured hydrogen loading approximately 6 mM. Optional low-intensity focused ultrasound immediately afterward for 20 min:1.1 MHz, 55.8 mW/cm², 50%duty cycle, 0.4 cm² focus. H₂-water comparator was also injected intravenously—not drunk. · 30% v/v perfluorooctylbromide nanoemulsion at 10 μL/g body weight after 60 minutes of coronary occlusion; hydrogen loading around 6 mM. Optional ultrasound: 1.1 MHz, 55.8 mW/cm², 50% duty cycle, 0.4 cm² focus, for 20 minutes. This was not drinking water or inhalation.

Duration

Acute reperfusion endpoints plus 28 day follow-up. Carrier fluorescence distribution assessed to 72 h; this describes carrier kinetics, not a measured 72 h lifetime of free hydrogen.

Reported result

The nanoemulsion held about 6 mM hydrogen, roughly 8 times the water comparator; ultrasound accelerated release. In this model, uptake was enriched in injured myocardium and in inflammatory monocyte/macrophage populations. Authors report smaller infarct fractions, lower injury/oxidative/pyroptosis markers and better cardiac outcomes with H₂-PFOB, particularly plus ultrasound, compared with their water and carrier controls. Area-at-risk/left-ventricle ratio did not differ significantly. At 28 days the text gives ejection-fraction values 57.4%, 54.7% and 48.8% in the comparison of combination, nanoemulsion and water groups. Acute EF/FS prose ambiguously describes decreases and percentages in an order inconsistent with the stated improvement; avoid republishing those acute percentages as verified absolute EF/FS. Survival is presented graphically; no precise mortality effect independently extracted. No obvious cell toxicity, organ histological lesions or significant measured liver/kidney/hematology changes were reported in limited short-term safety assays. This does not establish human intravenous safety.

Main limitation

Animal/cell nanomaterial study, not an inhalation or oral-water trial in patients.

Evidence and classification

What kind of evidence is this?

Evidence type

Preclinical

Reported design

Balb/c mouse coronary-occlusion/reperfusion study with imaging, mechanistic and 28 day outcome experiments; complementary primary-cell tests. Echocardiography was performed by an operator blinded to assignment. Overall randomization and total unique-animal count were not fully described.

Research topic

Cardiovascular and circulatory health

Administration form

Other forms

Study result signal

Mixed preclinical findings

Outcome type

H₂ storage/release, myocardial uptake, 19 F-MRI signal, infarct-area/area-at-risk ratio, troponin/LDH, echocardiography, FDG-PET, oxidative-stress and pyroptosis markers, survival curves, fibrosis and short-term biochemistry/histology.

Reported in the source

Methods

Population or model

Mouse myocardial ischemia–reperfusion models and primary-cell experiments; no human participants.

Sample

Balb/c mice 22–25 g. Acute infarct/serum endpoints n=7/group, acute echocardiography n=15/group, fluorescence/MRI/flow/protein assays typically n=5, 28 day cardiac structure n=7, several fibrosis/BNP endpoints n=5. These are separate endpoint counts and cannot be summed to infer a verified unique-animal total. Sex not specified in main animal section.

Duration

Acute reperfusion endpoints plus 28 day follow-up. Carrier fluorescence distribution assessed to 72 h; this describes carrier kinetics, not a measured 72 h lifetime of free hydrogen.

Intervention

Tail-vein H₂-loaded perfluorooctylbromide nanoemulsion, 30%v/v PFOB at 10 µL/g body weight, given at reperfusion after 60 min coronary occlusion. Measured hydrogen loading approximately 6 mM. Optional low-intensity focused ultrasound immediately afterward for 20 min:1.1 MHz, 55.8 mW/cm², 50%duty cycle, 0.4 cm² focus. H₂-water comparator was also injected intravenously—not drunk.

Hydrogen form

Intravenous hydrogen-loaded perfluorocarbon nanoemulsion, with optional focused ultrasound. The hydrogen-water comparator was also intravenous.

Dose or H₂ specification

30% v/v perfluorooctylbromide nanoemulsion at 10 μL/g body weight after 60 minutes of coronary occlusion; hydrogen loading around 6 mM. Optional ultrasound: 1.1 MHz, 55.8 mW/cm², 50% duty cycle, 0.4 cm² focus, for 20 minutes. This was not drinking water or inhalation.

Comparator

Sham and ischemia–reperfusion controls; non-hydrogenated PFOB; intravenously administered H₂-water; H₂-PFOB with or without ultrasound, as shown in respective experimental figures. Endpoint groups vary; do not claim all assays had the same n.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

H₂ storage/release, myocardial uptake, 19 F-MRI signal, infarct-area/area-at-risk ratio, troponin/LDH, echocardiography, FDG-PET, oxidative-stress and pyroptosis markers, survival curves, fibrosis and short-term biochemistry/histology.

Reported result

The nanoemulsion held about 6 mM hydrogen, roughly 8 times the water comparator; ultrasound accelerated release. In this model, uptake was enriched in injured myocardium and in inflammatory monocyte/macrophage populations. Authors report smaller infarct fractions, lower injury/oxidative/pyroptosis markers and better cardiac outcomes with H₂-PFOB, particularly plus ultrasound, compared with their water and carrier controls. Area-at-risk/left-ventricle ratio did not differ significantly. At 28 days the text gives ejection-fraction values 57.4%, 54.7% and 48.8% in the comparison of combination, nanoemulsion and water groups. Acute EF/FS prose ambiguously describes decreases and percentages in an order inconsistent with the stated improvement; avoid republishing those acute percentages as verified absolute EF/FS. Survival is presented graphically; no precise mortality effect independently extracted. No obvious cell toxicity, organ histological lesions or significant measured liver/kidney/hematology changes were reported in limited short-term safety assays. This does not establish human intravenous safety.

Extraction completeness

Published main text reviewed; supplementary PDF access not confirmed. Supplementary-only details were not independently checked. Acute cardiac-percentage ambiguities remain explicit.

Reported adverse events

Selected short-term safety observations are reported in Results; no comprehensive clinical safety assessment was performed.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

Animal/cell nanomaterial study, not an inhalation or oral-water trial in patients. Delivery carrier, ultrasound and hydrogen loading differ across groups; enhanced delivery cannot be assumed for consumer devices. Exact total unique animals, allocation/attrition and several methods are incomplete. Acute EF/FS numerical wording is internally unclear. Supporting PDF could not be retrieved through PMC/publisher routes at this review. Do not label supplements reviewed; supplementary-only safety and cell details remain author-reported in the main text. No independent raw-data reanalysis, formal image forensics or proof of clinical efficacy.

Applies directly to

The population or experimental model and protocol described here; clinical benefit and general safety are not established.

Funding and support

NSFC 81871459; Heilongjiang Tou-Yan Innovation Team 2019-15; Fourth Affiliated Hospital of Harbin Medical UniversityHYDSYTB 202001; Heilongjiang Key R&D SC 2022 ZX 06 C 0012.

Conflicts of interest

Authors declare no conflict of interest.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

PMID: 37596718 · DOI: 10.1002/advs.202304178

Publisher access

Published main full text available through the linked original source.

Editorial verification

Source verification based on the supplied publication review. This is editorial extraction, not independent medical or statistical validation.

Source sections checked

Complete published main text. Supplementary PDF inaccessible; not reviewed.

Extraction basis

Complete published main full-text article reviewed. Supplementary review scope is stated separately; no independent medical, statistical or image-forensic validation.

Last reviewed

22 November 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy

Send the exact difference between this page and the linked source. The study reference is attached automatically.