Languages

Read Hydrogenology in your language

Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

The impact of hydrogen inhalation therapy on blood reactive oxygen species levels: A randomized controlled study

Chair M, AlAani H, Lafci Fahrioglu S, Ben Hamda C, Fahrioglu U, Degheidy T. · Free Radic Biol Med. 2024;222:601-606.

HumanInhaled H₂Published 2024Source checked
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

A small study found lower peroxide-test readings 24 hours after a hydrogen-inhalation session. The groups already differed at baseline, and the immediate controlled comparison was null. The result does not establish a health benefit.

Source data warningBaseline endpoint imbalance and separate time-point tests, without a clearly documented baseline-adjusted treatment-effect model, limit the 24-hour comparison and raise regression-to-the-mean concerns.
Evidence type

Human

Population or model

Adults selected for d-ROMs above 350 U.CARR, not a disease-treatment cohort. Hydrogen: fourteen men/four women, mean age 33 (25–45); control: nine men/ten women, mean age 35.8 (22–48).

Intervention and dose

One-hour hydrogen-inhalation session by nasal cannula using HueLight H-2000 and sterile distilled water. Methods 2.2 lists generator production specifications but does not establish oxygen coadministration. No sham or oxygen-matched control. · Source purity above 99.99% is a generator specification, not actual patient inspired H₂ concentration. Inspired fraction and delivered patient dose were not measured/reported.

Duration

Single one-hour session; baseline, immediately after one hour and 24-hour measurements.

Reported result

Within hydrogen: immediate paired t = 3.79, P = 0.001458; 24-hour t = 6.49, P = 0.000006. Mean individual reductions 15.0% immediately (range −8.8 to 39.7%) and 23.3% at 24 hours (4.5 to 43.8%). The immediate between-group result was null: F = 0.05, P = 0.8196. At 24 hours F = 6.57, P = 0.0149. Baseline already differed: F = 7.61, P = 0.0092. Control time changes were nonsignificant; age P = 0.247 was nonsignificant, but sex composition differed.

Main limitation

Small, unblinded, one session and 24-hour follow-up, no sham, unclear allocation methods, baseline/sex imbalances and multiple surrogate tests. Oxygen coadministration is unknown. Manufacturer hosting and generator specifications do not establish independent exposure validation or clinical benefit.

Evidence and classification

What kind of evidence is this?

Evidence type

Human

Reported design

Randomized two-arm parallel study; laboratory collection/analysis staff blinded, participants unblinded because there was no placebo device. Sequence generation and concealment were not explained.

Research topic

Other molecular hydrogen research

Administration form

Inhaled H₂

Information not yet classified

Some editorial classification fields are still pending. The source-reported outcomes and result are shown below; Hydrogenology does not infer a positive or negative signal from prose automatically.

Reported in the source

Methods

Population or model

Adults selected for d-ROMs above 350 U.CARR, not a disease-treatment cohort. Hydrogen: fourteen men/four women, mean age 33 (25–45); control: nine men/ten women, mean age 35.8 (22–48).

Sample

67 screened; thirty excluded for lower d-ROMs; 37 enrolled and allocated: eighteen hydrogen, nineteen untreated control. All 37 are represented in results; no losses described.

Duration

Single one-hour session; baseline, immediately after one hour and 24-hour measurements.

Intervention

One-hour hydrogen-inhalation session by nasal cannula using HueLight H-2000 and sterile distilled water. Methods 2.2 lists generator production specifications but does not establish oxygen coadministration. No sham or oxygen-matched control.

Hydrogen form

Hydrogen inhalation by nasal cannula. Oxygen coadministration was not specified in Methods 2.2.

Dose or H₂ specification

Source purity above 99.99% is a generator specification, not actual patient inspired H₂ concentration. Inspired fraction and delivered patient dose were not measured/reported.

H₂ flow

Generator production specifications: H₂ 1,447 mL/min and O₂ 723 mL/min, pressure 1 bar. These are generated outputs, not measured delivery to participants. The article does not state that the generated O₂ was coadministered.

O₂ delivered with H₂

Oxygen coadministration and inspired oxygen fraction were not specified. The generator O₂ production specification of 723 mL/min is not a patient-delivery measurement.

Comparator

Untreated control without inhalation or sham apparatus.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

FRAS5 d-ROMs plasma-peroxide assay, a surrogate; not a direct measurement of all ROS. No clinical symptom or disease endpoint.

Reported result

Within hydrogen: immediate paired t = 3.79, P = 0.001458; 24-hour t = 6.49, P = 0.000006. Mean individual reductions 15.0% immediately (range −8.8 to 39.7%) and 23.3% at 24 hours (4.5 to 43.8%). The immediate between-group result was null: F = 0.05, P = 0.8196. At 24 hours F = 6.57, P = 0.0149. Baseline already differed: F = 7.61, P = 0.0092. Control time changes were nonsignificant; age P = 0.247 was nonsignificant, but sex composition differed.

Extraction completeness

Main-text methods, results, limitations and declarations were reviewed. Source versions, missing information and conflicting findings are stated in this record.

Reported adverse events

No systematic adverse-event methods/results stated; safety cannot be inferred from silence.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

Small, unblinded, one session and 24-hour follow-up, no sham, unclear allocation methods, baseline/sex imbalances and multiple surrogate tests. Oxygen coadministration is unknown. Manufacturer hosting and generator specifications do not establish independent exposure validation or clinical benefit.

Applies directly to

Limited to the population/model and protocol described above. These findings do not provide a treatment, concentration or device recommendation.

Funding and support

Authors report no specific public, commercial or nonprofit grant.

Conflicts of interest

Authors declare no identifiable conflicting financial interests or personal relationships. The paper discloses ChatGPT 3.5 language correction.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

PMID: 38996821 · DOI: 10.1016/j.freeradbiomed.2024.07.010

Publisher access

Complete final journal article, Free Radical Biology and Medicine 222, 601–606, hosted by HueLight, the manufacturer of the studied device. Hosting does not constitute independent device testing.

Editorial verification

AI-assisted editorial review of the available main full text, 29 October 2026. No independent clinical or statistical assessment has been performed.

Source sections checked

Pages 601–606: Methods 2.1–2.4, Results/statistics 3.1–3.3, Figures 1–4, limitations, funding, contributions and competing interests.

Extraction basis

AI-assisted editorial review of the available main full text, 29 October 2026. Complete final journal article, Free Radical Biology and Medicine 222, 601–606, hosted by HueLight, the manufacturer of the studied device. Hosting does not constitute independent device testing.

Registry / related-source limitations

No registration reported; ethics Cyprus International University EKK23-24/008/11.

Last reviewed

29 October 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 692 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy

Send the exact difference between this page and the linked source. The study reference is attached automatically.