Appearance of Psychophysiological Effect of Hydrogen Inhalation and Effect of Continuous Use on the Skin Properties
Takehara T, Hayashi Y, Fujishiro M, Kitamura E, Yada Y. · Journal of Japanese Cosmetic Science Society. 2022;46(1):8–19.
Study at a glance
This paper reports two small studies in healthy women. One examined brief inhalation from a portable hydrogen-and-oxygen generator; the other compared two weeks of use plus usual skin care with usual skin care alone. The authors reported changes in selected mood, pupil, skin-temperature and skin-appearance measurements. Several other outcomes, including skin hydration, water loss, pores, wrinkles, texture and facial blood flow, did not differ significantly. The longer study had no sham-device control, and many outcomes were tested. Inspired hydrogen concentration was estimated rather than measured, and the device also generated oxygen. Commercial affiliations and inconsistent reporting of the brain-measurement sample size add uncertainty. The results are exploratory and do not establish treatment of stress, skin disease or ageing.
Human
Healthy women aged 25–39; the continuous-use experiment selected women reporting stress-related skin changes.
KENCOSIII portable electrolysis device (AquaBank), with source outputs of 8 mL/min H₂ and 4 mL/min O₂, breathed naturally from the outlet. Acute testing used five minutes before peripheral measurements and another five minutes before NIRS. Continuous-use target: five minutes per session, five sessions daily for two weeks. · Device output: 8 mL/min H₂ plus 4 mL/min O₂. The paper’s arithmetic maximum of 0.16% H₂ and 0.08% added O₂ assumes complete gas capture and breathing of 5 L/min; these are not measured inspired fractions.
Acute conditions on test visits. Continuous crossover: two two-week periods, with assessments at weeks 0, 2 and 4. No clear washout was described.
Acute fatigue/stress ratings and selected negative-mood items were lower, while selected concentration/liveliness items were higher, without uniform improvement across questionnaires. Miosis and finger temperature increased (mean finger-temperature change 3.6°C); mydriatic velocity and forehead temperature were unchanged. Flicker value was 43.9 ± 1.3 versus 42.1 ± 1.7, p < .05. Selected NIRS oxyhemoglobin channels increased, with an unresolved n = 17 versus 22 discrepancy. After two weeks, SCL30 change was −2.20 versus +.10, with a reported between-period difference. R7 elasticity changed +.01 versus −.01 (p = .028), R2 +.01 versus −.02 (p = .016); VISIA blotches −1.8 versus +4.7 (p = .012), brown spots −13.7 versus +3.8 (p = .046) and redness −5.1 versus +3.2 (p = .042). Skin hydration, transepidermal water loss, instrumental skin color, porphyrins, facial blood flow, pores, wrinkles and texture did not differ significantly.
The two-week experiment had no sham-device control and tested many outcomes. The two samples of 22 women cannot be assumed to represent 44 unique participants.
What kind of evidence is this?
Human
Acute randomized-order crossover with device-off control, followed by two-period crossover comparing two weeks of hydrogen use plus usual skin care with usual skin care alone. Randomization of the longer-period sequence was unclear.
Skin, wound and aging research
Inhaled H₂
Mixed or exploratory findings
Acute mood, fatigue, pupil, temperature, flicker and NIRS measurements; two-week stress and instrumental skin measurements.
Methods
Healthy women aged 25–39; the continuous-use experiment selected women reporting stress-related skin changes.
Acute experiment: 22 women, mean age 31.3 ± 5.6 years. Continuous-use experiment: 22 women, mean age 30.2 ± 4.3. Overlap between experiments was not stated, so these are not necessarily 44 unique participants. NIRS analysis is reported as n = 17 in text but n = 22 in the Figure 7 caption.
Acute conditions on test visits. Continuous crossover: two two-week periods, with assessments at weeks 0, 2 and 4. No clear washout was described.
KENCOSIII portable electrolysis device (AquaBank), with source outputs of 8 mL/min H₂ and 4 mL/min O₂, breathed naturally from the outlet. Acute testing used five minutes before peripheral measurements and another five minutes before NIRS. Continuous-use target: five minutes per session, five sessions daily for two weeks.
Inhaled co-generated hydrogen and oxygen; personal inspired concentration was not measured.
Device output: 8 mL/min H₂ plus 4 mL/min O₂. The paper’s arithmetic maximum of 0.16% H₂ and 0.08% added O₂ assumes complete gas capture and breathing of 5 L/min; these are not measured inspired fractions.
8 mL/min H₂ at the device outlet; captured personal exposure was not measured.
4 mL/min co-generated O₂ at the device outlet; this is not measured inspired oxygen concentration.
Acute: device-off breathing, random-order groups of 11. Continuous use: usual skin care alone, without a sham inhaler. Usual cosmetics and supplements continued unchanged.
Outcomes and reported result
Acute mood, fatigue, pupil, temperature, flicker and NIRS measurements; two-week stress and instrumental skin measurements.
Acute fatigue/stress ratings and selected negative-mood items were lower, while selected concentration/liveliness items were higher, without uniform improvement across questionnaires. Miosis and finger temperature increased (mean finger-temperature change 3.6°C); mydriatic velocity and forehead temperature were unchanged. Flicker value was 43.9 ± 1.3 versus 42.1 ± 1.7, p < .05. Selected NIRS oxyhemoglobin channels increased, with an unresolved n = 17 versus 22 discrepancy. After two weeks, SCL30 change was −2.20 versus +.10, with a reported between-period difference. R7 elasticity changed +.01 versus −.01 (p = .028), R2 +.01 versus −.02 (p = .016); VISIA blotches −1.8 versus +4.7 (p = .012), brown spots −13.7 versus +3.8 (p = .046) and redness −5.1 versus +3.2 (p = .042). Skin hydration, transepidermal water loss, instrumental skin color, porphyrins, facial blood flow, pores, wrinkles and texture did not differ significantly.
Complete published main text reviewed, with source uncertainties and unreported details retained. No independent reanalysis.
No systematic adverse-event results were provided; absence of reported events does not establish safety.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Small, short studies in women aged 25–39 with possible expectation effects. Longer-period randomization, washout and carryover adjustment were unclear. Many questionnaire, skin, physiological and NIRS comparisons lacked clear overall multiplicity control; nominal p values are exploratory. Text and caption disagree on NIRS sample size, and Figure 2 labels N₂ although primary methods describe H₂/O₂ electrolysis gas. Actual inspired H₂ was not measured. Co-generated oxygen prevents a pure-hydrogen contrast. Broad claims about skin and blood flow conflict with several null Results outcomes. No standardized long-term safety evaluation, objective clinical dermatology endpoint or independent replication.
The described study population or experimental model only; clinical efficacy and safety are not established.
The article states “Funding: Not applicable.”
Authors declare no competing interests. Takehara and Hayashi were affiliated with AquaBank, manufacturer of the studied device; Fujishiro and Kitamura with product development at Cosmos Technical Center. These commercial affiliations remain relevant to interpretation.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
Source ID: doi-10.11469-koshohin.46.8 · DOI: 10.11469/koshohin.46.8
Published open-access article at the linked original source.
Source verification based on the supplied publication review. This is not independent medical or statistical validation.
Published main text, tables, figures, references and disclosures.
Complete published full-text article reviewed, including main methods, results, tables, figures, discussion and disclosures.
18 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.