Effects of hydrogen-occluding-silica microparticles on wound repair and cell migratory behavior of normal human esophageal epitheliocytes
Li Q, Tanaka Y, Miwa N. · Medical Gas Research. 2018;8(2):57–63.
Study at a glance
Researchers tested a hydrogen-containing silica preparation on normal human esophageal cells grown in the laboratory. Lower material concentrations were associated with faster closure of a scratch in the cell layer and changes in cell movement. Higher concentrations suppressed growth and produced signs of cell toxicity and apoptosis. This was not a study in people with wounds. The reported ppm values describe the silica material, not measured dissolved hydrogen, and the design does not separate hydrogen effects from those of the particles. The results cannot establish clinical wound-healing benefits or the safety of a consumer hydrogen product.
Preclinical
Normal human esophageal epithelial cells grown in culture; no human participants.
Hydrogen-occluding silica hydride Microcluster from New-1-Ten-Rin Enterprise; material concentrations listed across methods as 10, 40, 70, 100, 300, 600, 900, 1200 ppm, with main scratch/Western-blot comparisons at 0, 10, 100, 300, 600, 1200 ppm. The ppm values describe the silica preparation in culture, not a measured concentration of dissolved H₂. pH, temperature and oxidation-reduction potential were reportedly measured before application, but the current report does not provide a quantified time course of H₂ release. · Reported material concentrations ranged from 10 to 1, 200 ppm, with major scratch comparisons at 0, 10, 100, 300, 600 and 1, 200 ppm. These values refer to silica preparation, not measured dissolved H₂. Actual hydrogen release was not quantified.
Culture preparation 72–96 hours followed by observations at 0, 24, 48, 72 hours after scratching; protein assays at around 72 hours.
At 10 and 100 ppm, the paper describes greater scratch closure/migration over 48–72 hours and prominent migration-related protrusions, especially at 100 ppm. Figure 1 indicates repeated-ANOVA P<0.01; exact robust effect-size estimates are not provided in the narrative and are not inferred from images. At 300 ppm and above, reduced nuclei/growth and apoptosis-like morphology were observed, with increased pro-apoptotic Bax/Bcl-2 signals in scratched cells and especially activated caspase-3 at 1200 ppm. Lower-dose fascin/cytoskeleton changes were reported, but not all ratios or conditions changed clearly. Results/Discussion and Figure 4 labeling are inconsistent about some caspase band weights and fascin/tubulin versus its reciprocal. The record retains qualitative trends rather than silently resolving those inconsistencies.
Cells only, no patients or intact tissue, and no demonstrated clinical wound healing.
What kind of evidence is this?
Preclinical
Laboratory scratched and non-scratched normal human esophageal epithelial cell cultures treated with hydrogen-occluding silica microparticles; scratch closure, cell morphology, F-actin staining and Western blots. A scratch assay in cultured esophageal cells is not an actual skin-wound trial.
Skin, wound and aging research
Other forms
Mixed preclinical findings
Scratch closure/migration, filopodia and microvilli morphology, DAPI nuclei, F-actin, activated caspase-3, Bax/Bcl-2 and fascin/tubulin ratios.
Methods
Normal human esophageal epithelial cells grown in culture; no human participants.
Commercial HEEpiCs from ScienCell, typically seeded 4×10⁵ cells/well in six-well plates or about 1×10⁶/T 25 flask for protein work. More than 20 microscopic fields/well were photographed for morphology, but an adequate independent biological replicate count is not clearly reported. Fields and cell seeding counts must not be treated as participant or independent-experiment counts. No human participants.
Culture preparation 72–96 hours followed by observations at 0, 24, 48, 72 hours after scratching; protein assays at around 72 hours.
Hydrogen-occluding silica hydride Microcluster from New-1-Ten-Rin Enterprise; material concentrations listed across methods as 10, 40, 70, 100, 300, 600, 900, 1200 ppm, with main scratch/Western-blot comparisons at 0, 10, 100, 300, 600, 1200 ppm. The ppm values describe the silica preparation in culture, not a measured concentration of dissolved H₂. pH, temperature and oxidation-reduction potential were reportedly measured before application, but the current report does not provide a quantified time course of H₂ release.
Hydrogen-containing silica material added to culture medium.
Reported material concentrations ranged from 10 to 1, 200 ppm, with major scratch comparisons at 0, 10, 100, 300, 600 and 1, 200 ppm. These values refer to silica preparation, not measured dissolved H₂. Actual hydrogen release was not quantified.
Untreated 0-ppm scratched/non-scratched cultures and comparisons between material concentrations. No matched hydrogen-free silica control or hydrogen-only exposure comparison is clearly described.
Outcomes and reported result
Scratch closure/migration, filopodia and microvilli morphology, DAPI nuclei, F-actin, activated caspase-3, Bax/Bcl-2 and fascin/tubulin ratios.
At 10 and 100 ppm, the paper describes greater scratch closure/migration over 48–72 hours and prominent migration-related protrusions, especially at 100 ppm. Figure 1 indicates repeated-ANOVA P<0.01; exact robust effect-size estimates are not provided in the narrative and are not inferred from images. At 300 ppm and above, reduced nuclei/growth and apoptosis-like morphology were observed, with increased pro-apoptotic Bax/Bcl-2 signals in scratched cells and especially activated caspase-3 at 1200 ppm. Lower-dose fascin/cytoskeleton changes were reported, but not all ratios or conditions changed clearly. Results/Discussion and Figure 4 labeling are inconsistent about some caspase band weights and fascin/tubulin versus its reciprocal. The record retains qualitative trends rather than silently resolving those inconsistencies.
Main full text reviewed; independent replicate count and H₂ release not adequately reported. Source inconsistencies, null results and unreported values are retained; no independent reanalysis.
No clinical adverse-event assessment; cell toxicity and apoptosis at higher material concentrations are central findings. The authors acknowledge silica particles themselves may contribute to toxicity.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Cells only, no patients or intact tissue, and no demonstrated clinical wound healing. Hydrogen-containing material does not isolate an H₂-specific effect; no clearly reported unloaded-silica control or actual dissolved-H₂ dose/release profile. Independent replicate counts and raw data are insufficiently specified; several molecular changes are described as tendencies; concentration-dependent toxicity prevents a simple benefit claim. The authors' statement that hydrogen water without silica is nontoxic at equivalent high H₂ concentrations was not established by the comparison performed here.
The population or experimental model and protocol described here; clinical benefit and general safety are not established.
Japan Ministry of Education, Culture, Sports, Science and Technology KAKENHI 26350681 to Qiang Li.
Authors declare no conflict. Material was kindly supplied by the manufacturer.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 30112167 · DOI: 10.4103/2045-9912.235128
Published main full text available through the linked original source.
Source verification based on the supplied publication review. This is editorial extraction, not independent medical or statistical validation.
Entire PMC main HTML read, all four figure legends and source-reported trends, methods/results/discussion/disclosures/references checked. No supplementary file linked; data stated available from corresponding author on reasonable request. No claim of independent image-forensic or raw-data validation.
Complete published main full-text article reviewed. Supplementary review scope is stated separately; no independent medical, statistical or image-forensic validation.
22 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.