Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

Effects of hydrogen-occluding-silica microparticles on wound repair and cell migratory behavior of normal human esophageal epitheliocytes

Li Q, Tanaka Y, Miwa N. · Medical Gas Research. 2018;8(2):57–63.

PreclinicalOther formsPublished 2018Main full text reviewed; independent replicate count and H₂ release not adequately reported
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

Researchers tested a hydrogen-containing silica preparation on normal human esophageal cells grown in the laboratory. Lower material concentrations were associated with faster closure of a scratch in the cell layer and changes in cell movement. Higher concentrations suppressed growth and produced signs of cell toxicity and apoptosis. This was not a study in people with wounds. The reported ppm values describe the silica material, not measured dissolved hydrogen, and the design does not separate hydrogen effects from those of the particles. The results cannot establish clinical wound-healing benefits or the safety of a consumer hydrogen product.

Source data warningHigher material concentrations produced growth suppression and apoptosis. The material ppm values are not dissolved-hydrogen concentrations, and independent culture replication and hydrogen release were incompletely documented.
Evidence type

Preclinical

Population or model

Normal human esophageal epithelial cells grown in culture; no human participants.

Intervention and dose

Hydrogen-occluding silica hydride Microcluster from New-1-Ten-Rin Enterprise; material concentrations listed across methods as 10, 40, 70, 100, 300, 600, 900, 1200 ppm, with main scratch/Western-blot comparisons at 0, 10, 100, 300, 600, 1200 ppm. The ppm values describe the silica preparation in culture, not a measured concentration of dissolved H₂. pH, temperature and oxidation-reduction potential were reportedly measured before application, but the current report does not provide a quantified time course of H₂ release. · Reported material concentrations ranged from 10 to 1, 200 ppm, with major scratch comparisons at 0, 10, 100, 300, 600 and 1, 200 ppm. These values refer to silica preparation, not measured dissolved H₂. Actual hydrogen release was not quantified.

Duration

Culture preparation 72–96 hours followed by observations at 0, 24, 48, 72 hours after scratching; protein assays at around 72 hours.

Reported result

At 10 and 100 ppm, the paper describes greater scratch closure/migration over 48–72 hours and prominent migration-related protrusions, especially at 100 ppm. Figure 1 indicates repeated-ANOVA P<0.01; exact robust effect-size estimates are not provided in the narrative and are not inferred from images. At 300 ppm and above, reduced nuclei/growth and apoptosis-like morphology were observed, with increased pro-apoptotic Bax/Bcl-2 signals in scratched cells and especially activated caspase-3 at 1200 ppm. Lower-dose fascin/cytoskeleton changes were reported, but not all ratios or conditions changed clearly. Results/Discussion and Figure 4 labeling are inconsistent about some caspase band weights and fascin/tubulin versus its reciprocal. The record retains qualitative trends rather than silently resolving those inconsistencies.

Main limitation

Cells only, no patients or intact tissue, and no demonstrated clinical wound healing.

Evidence and classification

What kind of evidence is this?

Evidence type

Preclinical

Reported design

Laboratory scratched and non-scratched normal human esophageal epithelial cell cultures treated with hydrogen-occluding silica microparticles; scratch closure, cell morphology, F-actin staining and Western blots. A scratch assay in cultured esophageal cells is not an actual skin-wound trial.

Research topic

Skin, wound and aging research

Administration form

Other forms

Study result signal

Mixed preclinical findings

Outcome type

Scratch closure/migration, filopodia and microvilli morphology, DAPI nuclei, F-actin, activated caspase-3, Bax/Bcl-2 and fascin/tubulin ratios.

Reported in the source

Methods

Population or model

Normal human esophageal epithelial cells grown in culture; no human participants.

Sample

Commercial HEEpiCs from ScienCell, typically seeded 4×10⁵ cells/well in six-well plates or about 1×10⁶/T 25 flask for protein work. More than 20 microscopic fields/well were photographed for morphology, but an adequate independent biological replicate count is not clearly reported. Fields and cell seeding counts must not be treated as participant or independent-experiment counts. No human participants.

Duration

Culture preparation 72–96 hours followed by observations at 0, 24, 48, 72 hours after scratching; protein assays at around 72 hours.

Intervention

Hydrogen-occluding silica hydride Microcluster from New-1-Ten-Rin Enterprise; material concentrations listed across methods as 10, 40, 70, 100, 300, 600, 900, 1200 ppm, with main scratch/Western-blot comparisons at 0, 10, 100, 300, 600, 1200 ppm. The ppm values describe the silica preparation in culture, not a measured concentration of dissolved H₂. pH, temperature and oxidation-reduction potential were reportedly measured before application, but the current report does not provide a quantified time course of H₂ release.

Hydrogen form

Hydrogen-containing silica material added to culture medium.

Dose or H₂ specification

Reported material concentrations ranged from 10 to 1, 200 ppm, with major scratch comparisons at 0, 10, 100, 300, 600 and 1, 200 ppm. These values refer to silica preparation, not measured dissolved H₂. Actual hydrogen release was not quantified.

Comparator

Untreated 0-ppm scratched/non-scratched cultures and comparisons between material concentrations. No matched hydrogen-free silica control or hydrogen-only exposure comparison is clearly described.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Scratch closure/migration, filopodia and microvilli morphology, DAPI nuclei, F-actin, activated caspase-3, Bax/Bcl-2 and fascin/tubulin ratios.

Reported result

At 10 and 100 ppm, the paper describes greater scratch closure/migration over 48–72 hours and prominent migration-related protrusions, especially at 100 ppm. Figure 1 indicates repeated-ANOVA P<0.01; exact robust effect-size estimates are not provided in the narrative and are not inferred from images. At 300 ppm and above, reduced nuclei/growth and apoptosis-like morphology were observed, with increased pro-apoptotic Bax/Bcl-2 signals in scratched cells and especially activated caspase-3 at 1200 ppm. Lower-dose fascin/cytoskeleton changes were reported, but not all ratios or conditions changed clearly. Results/Discussion and Figure 4 labeling are inconsistent about some caspase band weights and fascin/tubulin versus its reciprocal. The record retains qualitative trends rather than silently resolving those inconsistencies.

Extraction completeness

Main full text reviewed; independent replicate count and H₂ release not adequately reported. Source inconsistencies, null results and unreported values are retained; no independent reanalysis.

Reported adverse events

No clinical adverse-event assessment; cell toxicity and apoptosis at higher material concentrations are central findings. The authors acknowledge silica particles themselves may contribute to toxicity.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

Cells only, no patients or intact tissue, and no demonstrated clinical wound healing. Hydrogen-containing material does not isolate an H₂-specific effect; no clearly reported unloaded-silica control or actual dissolved-H₂ dose/release profile. Independent replicate counts and raw data are insufficiently specified; several molecular changes are described as tendencies; concentration-dependent toxicity prevents a simple benefit claim. The authors' statement that hydrogen water without silica is nontoxic at equivalent high H₂ concentrations was not established by the comparison performed here.

Applies directly to

The population or experimental model and protocol described here; clinical benefit and general safety are not established.

Funding and support

Japan Ministry of Education, Culture, Sports, Science and Technology KAKENHI 26350681 to Qiang Li.

Conflicts of interest

Authors declare no conflict. Material was kindly supplied by the manufacturer.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

PMID: 30112167 · DOI: 10.4103/2045-9912.235128

Publisher access

Published main full text available through the linked original source.

Editorial verification

Source verification based on the supplied publication review. This is editorial extraction, not independent medical or statistical validation.

Source sections checked

Entire PMC main HTML read, all four figure legends and source-reported trends, methods/results/discussion/disclosures/references checked. No supplementary file linked; data stated available from corresponding author on reasonable request. No claim of independent image-forensic or raw-data validation.

Extraction basis

Complete published main full-text article reviewed. Supplementary review scope is stated separately; no independent medical, statistical or image-forensic validation.

Last reviewed

22 November 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy

Send the exact difference between this page and the linked source. The study reference is attached automatically.