Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

Degradation products of magnesium implant synergistically enhance bone regeneration: Unraveling the roles of hydrogen gas and alkaline environment

An Y, Zhang H, Zhang S, Zhang Y, Zheng L, Chen X, Tong W, Xu J, Qin L. · Bioactive materials. 2025;46:331-346.

PreclinicalOther formsPublished 2025Full text reviewed
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

Source data warningSeparate water/saline hydrogen dose and schedule are incomplete. Unique animal total and some group sizes remain unclear.
Evidence type

Preclinical

Population or model

Female ovariectomized rats and mice with femoral fractures; rat femoral implants, isolated periosteum and dorsal-root ganglia.

Intervention and dose

Magnesium-containing intramedullary implants, compared with steel or salt-filled implants; additional hydrogen-water/saline supplementation and hydrogen-rich tissue-culture media. Rat magnesium insert: 99.99% magnesium, 0.7 mm diameter and 1.5 cm length. Local hydrogen and pH were measured; independent water/saline concentration, injected volume and exact dosing frequency are not adequately specified.

Duration

Main biological outcomes over the first two weeks after fracture; local gas/pH measured days 3–15. Material composition was also examined to 12 weeks. Ex vivo exposure generally 2 or 24 hours.

Reported result

Magnesium implants and the hydrogen-supplemented arm showed greater early bone formation than steel controls. Tissue experiments suggested distinct contributions from hydrogen, magnesium ions and local alkalinity; substance P release did not change, and some effects attributed to hydrogen were absent with magnesium or alkalinity alone. The combined implant effects cannot be assigned to hydrogen alone because the component doses were not matched. Later functional fracture healing and outcomes in people were not established.

Main limitation

Complex combined-material intervention, incompletely specified separate hydrogen dosing, and mainly early surrogate healing outcomes.

Evidence and classification

What kind of evidence is this?

Evidence type

Preclinical

Reported design

Controlled rodent implant and osteoporotic-fracture experiments, with ex vivo tissue tests and exploratory transcriptomics separating magnesium degradation products.

Research topic

Musculoskeletal and pain research

Administration form

Other forms

Information not yet classified

Some editorial classification fields are still pending. The source-reported outcomes and result are shown below; Hydrogenology does not infer a positive or negative signal from prose automatically.

Reported in the source

Methods

Population or model

Female ovariectomized rats and mice with femoral fractures; rat femoral implants, isolated periosteum and dorsal-root ganglia.

Sample

Multiple cohorts with assay-level n generally 3–8; fracture micro-CT comparisons used six animals per group. Ex vivo sequencing combined tissues from four rats per sample, using 8–12 rats per group. A study-wide total is not given, and distal-femur methods n = 4 conflicts with some figure samples of 5–7.

Duration

Main biological outcomes over the first two weeks after fracture; local gas/pH measured days 3–15. Material composition was also examined to 12 weeks. Ex vivo exposure generally 2 or 24 hours.

Intervention

Magnesium-containing intramedullary implants, compared with steel or salt-filled implants; additional hydrogen-water/saline supplementation and hydrogen-rich tissue-culture media.

Hydrogen form

Hydrogen generated locally by magnesium corrosion, plus dissolved hydrogen in water, saline and culture media.

Dose or H₂ specification

Rat magnesium insert: 99.99% magnesium, 0.7 mm diameter and 1.5 cm length. Local hydrogen and pH were measured; independent water/saline concentration, injected volume and exact dosing frequency are not adequately specified.

Comparator

Stainless-steel implants, and implants containing magnesium hydroxide, magnesium chloride or sodium hydroxide; untreated tissue and corresponding media controls.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Local hydrogen/pH and material degradation; fracture callus, bone volume/density and histology; sensory/sympathetic signalling, CGRP/substance P and tissue gene expression.

Reported result

Magnesium implants and the hydrogen-supplemented arm showed greater early bone formation than steel controls. Tissue experiments suggested distinct contributions from hydrogen, magnesium ions and local alkalinity; substance P release did not change, and some effects attributed to hydrogen were absent with magnesium or alkalinity alone. The combined implant effects cannot be assigned to hydrogen alone because the component doses were not matched. Later functional fracture healing and outcomes in people were not established.

Extraction completeness

Full-text editorial synthesis; unresolved reporting details are stated explicitly.

Reported adverse events

Authors reported no swelling, bleeding or clinically apparent gas pockets at the fracture site; small transient callus voids were described histologically. This was not a comprehensive systemic safety study.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

No equivalent-dose isolation of each degradation product; tissue RNA pooling and inconsistent sample descriptions. Discussion and results give different peak marrow-hydrogen values. The exposure is not solely drinking hydrogen water.

Applies directly to

Early rodent osteoporotic bone repair and isolated rodent tissues.

Funding and support

Hong Kong Research Grants Council Areas of Excellence AoE/M-402/20 and General Research Fund 14109421. Authors declared no competing interests.

Conflicts of interest

Hong Kong Research Grants Council Areas of Excellence AoE/M-402/20 and General Research Fund 14109421. Authors declared no competing interests.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

PMID: 39816475 · DOI: 10.1016/j.bioactmat.2024.12.020

Publisher access

A free full article is available through PubMed Central.

Editorial verification

AI-assisted editorial review of the original full-text methods, results, limitations and disclosures for the specified replacement fields; not independent clinical or statistical validation.

Extraction basis

Original full-text methods, results, figures/tables, discussion and disclosures reviewed. AI-assisted editorial extraction; not an independent medical review.

Last reviewed

11 November 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy

Send the exact difference between this page and the linked source. The study reference is attached automatically.