Automatic translation noticeHydrogenology was originally written in English. The name Hydrogenology is a proper name and is never translated. Other language versions are translated automatically with AI and may contain inaccuracies, especially in scientific or medical terminology. When precision matters, consult the English version and the linked original source.

Selecting a language opens an automatic Google translation of the current page. You can also use your browser's built-in translation option; in Chrome, use the Translate icon in the address bar or right-click the page and choose Translate. Google Chrome translation help ↗

Europe

Widely spoken languages

Hydrogenology
Source-linked study record

Nanocatalytic anti-inflammatory therapy for alleviating rheumatoid lesions with endothelial cell-derived hydrosilicene.

Dong J, Yu W, Huang M, Li Z, Lu Y, Chen J, Chen Z, Zhang X. · Journal of Nanobiotechnology. 2026;24:1055.

PreclinicalOther formsPublished 2026Published complete main text and supplementary DOCX reviewed
Study record, not medical adviceThis record reports what the source states. It is not medical advice and does not establish that molecular hydrogen is effective, safe or appropriate for any person.
Quick summary

Study at a glance

Researchers tested hydrogen-releasing silicon nanosheets coated with endothelial-cell membranes in laboratory assays and mice with experimentally induced arthritis. The coating helped the material attach to activated neutrophils, and treated mice showed less joint inflammation and better bone/cartilage measurements than untreated arthritic controls. Human neutrophils came from one healthy donor; no patients received the treatment. The experiments were small, the treatment-start descriptions conflict, and the effects of hydrogen cannot be fully separated from the silicon material and its membrane coating. These findings do not show that inhaled hydrogen or hydrogen water treats rheumatoid arthritis.

Source data warningOne donor supplied neutrophils, but no human was treated. Treatment-start descriptions conflict. Silicon, membrane coating and hydrogen effects are not fully separated; material mass is not H₂ dose.
Evidence type

Preclinical

Population or model

Endothelial-cell cultures, neutrophils from one healthy donor and male DBA/1 mice with collagen-induced arthritis; no treated patients.

Intervention and dose

HUVEC-membrane-coated hydrosilicene nanosheets (HSI@ECM), hydrogen-generating silicon-based material, approximately 300 nm lateral size and <15 nm thickness. Neutrophil exposure commonly 100 micrograms material/mL. Arthritis treatment: 100 micrograms material/mL, 10 microlitres/paw by hind-footpad injection every other day (1 microgram material/paw); this is material mass, not an administered H2 gas dose. Collagen 100 micrograms plus CFA at primary immunization, IFA booster day 21. · HUVEC-membrane-coated hydrosilicene nanosheets (HSI@ECM), hydrogen-generating silicon-based material, approximately 300 nm lateral size and <15 nm thickness. Neutrophil exposure commonly 100 micrograms material/mL. Arthritis treatment: 100 micrograms material/mL, 10 microlitres/paw by hind-footpad injection every other day (1 microgram material/paw); this is material mass, not an administered H2 gas dose. Collagen 100 micrograms plus CFA at primary immunization, IFA booster day 21.

Duration

Arthritis evaluation at 6 and 9 weeks; injection start is inconsistent: methods describe assignment at day 28, whereas results describe treatment from primary immunization. Cell toxicity evaluated at 24/48/72 h.

Reported result

The coated material showed stronger adhesion to activated neutrophils than uncoated/red-cell-coated controls and reduced pathological ROS and NET-related signals in experimental assays. Basal neutrophil ROS was not significantly altered in the supplementary comparisons. In arthritic mice the authors reported lower arthritis scores, paw swelling and temperature and better bone/cartilage measures with HSI@ECM than disease controls; figures generally favour the coated material over uncoated HSI. Numerical whole-animal effect sizes were not extracted from graph pixels. HUVEC viability was not significantly reduced in the short culture assays at the investigated concentrations up to 200 micrograms/mL. This is a limited cell screen, not comprehensive systemic safety testing.

Main limitation

Single healthy-donor neutrophils do not establish effects in rheumatoid-arthritis patients; n=3 measurements must not be presented as three human participants.

Evidence and classification

What kind of evidence is this?

Evidence type

Preclinical

Reported design

Cell/material experiments, ex vivo healthy-donor neutrophils and collagen-induced arthritis in male DBA/1 mice; not a human treatment study.

Research topic

Musculoskeletal and pain research

Administration form

Other forms

Study result signal

Preclinical findings with attribution limits

Outcome type

Arthritis index, paw swelling/temperature, micro-CT bone microstructure, cartilage histology/Mankin score, ROS, NET markers MPO/NE/CitH3/PAD4, mitochondrial membrane-potential assays and material biocompatibility.

Reported in the source

Methods

Population or model

Endothelial-cell cultures, neutrophils from one healthy donor and male DBA/1 mice with collagen-induced arthritis; no treated patients.

Sample

Neutrophils from one healthy human donor; HUVEC culture assays. Male DBA/1 mice aged 6–8 weeks; figure captions specify n=4/group for arthritis/histological endpoints, with n=3 for several cell assays. Total unique mice across 6- and 9-week endpoints is not transparently mapped.

Duration

Arthritis evaluation at 6 and 9 weeks; injection start is inconsistent: methods describe assignment at day 28, whereas results describe treatment from primary immunization. Cell toxicity evaluated at 24/48/72 h.

Intervention

HUVEC-membrane-coated hydrosilicene nanosheets (HSI@ECM), hydrogen-generating silicon-based material, approximately 300 nm lateral size and <15 nm thickness. Neutrophil exposure commonly 100 micrograms material/mL. Arthritis treatment: 100 micrograms material/mL, 10 microlitres/paw by hind-footpad injection every other day (1 microgram material/paw); this is material mass, not an administered H2 gas dose. Collagen 100 micrograms plus CFA at primary immunization, IFA booster day 21.

Hydrogen form

Hydrogen-generating silicon nanosheets delivered by local footpad injection.

Dose or H₂ specification

HUVEC-membrane-coated hydrosilicene nanosheets (HSI@ECM), hydrogen-generating silicon-based material, approximately 300 nm lateral size and <15 nm thickness. Neutrophil exposure commonly 100 micrograms material/mL. Arthritis treatment: 100 micrograms material/mL, 10 microlitres/paw by hind-footpad injection every other day (1 microgram material/paw); this is material mass, not an administered H2 gas dose. Collagen 100 micrograms plus CFA at primary immunization, IFA booster day 21.

Comparator

Healthy control; arthritis plus PBS; uncoated HSI; membrane-coated HSI; methotrexate 5 mg/kg. Cell work includes PMA-stimulated controls, NAC 10 mM, and red-cell-membrane-coated material in adhesion experiments.

Reported, not endorsed

Outcomes and reported result

Outcomes measured

Arthritis index, paw swelling/temperature, micro-CT bone microstructure, cartilage histology/Mankin score, ROS, NET markers MPO/NE/CitH3/PAD4, mitochondrial membrane-potential assays and material biocompatibility.

Reported result

The coated material showed stronger adhesion to activated neutrophils than uncoated/red-cell-coated controls and reduced pathological ROS and NET-related signals in experimental assays. Basal neutrophil ROS was not significantly altered in the supplementary comparisons. In arthritic mice the authors reported lower arthritis scores, paw swelling and temperature and better bone/cartilage measures with HSI@ECM than disease controls; figures generally favour the coated material over uncoated HSI. Numerical whole-animal effect sizes were not extracted from graph pixels. HUVEC viability was not significantly reduced in the short culture assays at the investigated concentrations up to 200 micrograms/mL. This is a limited cell screen, not comprehensive systemic safety testing.

Extraction completeness

Published complete main text and supplementary DOCX reviewed. Complete supplementary DOCX text/captions S1–S10 reviewed and embedded raster images inspected; vector panels were not independently digitized. Null findings, source inconsistencies and unreported values are retained; no independent reanalysis.

Reported adverse events

No significant short-term endothelial-cell cytotoxicity reported; comprehensive animal adverse-event surveillance, chronic clearance and toxicity were not established.

A reported association, difference or mechanism is not automatically a clinical benefit.

Interpretation limits

Limitations and applicability

Main methodological cautions

Single healthy-donor neutrophils do not establish effects in rheumatoid-arthritis patients; n=3 measurements must not be presented as three human participants. Small animal endpoint groups; no prospective power calculation or clear blinded outcome assessment identified. Total unique animal allocation and treatment timing are incompletely reconciled. Composite H2-generating silicon/membrane intervention: material targeting, silicon chemistry and H2 effects are not fully separated by a matched gas-only comparator. Actual in vivo H2 exposure is not established by material concentration. PMA activation is an artificial neutrophil model; proposed ROS/NET causal mechanisms remain preliminary. No clinical efficacy, inhaler/water efficacy or long-term systemic safety conclusion is justified.

Applies directly to

The reported population or experimental model and protocol only; clinical benefit and general safety are not established.

Funding and support

National Natural Science Foundation of China 82302777.

Conflicts of interest

Authors declare no competing interests.

No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.

Sources and status

Sources and record status

Identifiers

PMID: 43009968 · DOI: 10.1186/s12951-026-04930-0

Publisher access

Published main full text available through the linked original source.

Publication status

No correction, retraction or expression-of-concern notice identified in supplied full text/metadata or targeted DOI searches on 24 November 2026. Limited notice screen, not an integrity certification.

Editorial verification

Editorial integration of the supplied source review; not independent medical or statistical validation.

Source sections checked

Complete published main XML read through disclosures. Supplementary DOCX text/captions S1–S10 read; embedded raster images inspected. Vector-only panels were not independently digitized; no numerical effects inferred from unreadable images. Supplementary scope: Complete supplementary DOCX text/captions S1–S10 reviewed and embedded raster images inspected; vector panels were not independently digitized.

Extraction basis

Complete published main full-text article reviewed using the supplied study-specific review packet. Supplementary scope is stated separately; no independent clinical, statistical or image-forensic validation.

Registry / related-source limitations

Ethics and consent reporting: Shanghai General Hospital human ethics 2024KS439 (one healthy donor); animal approval 2024SC030. Related-data limitations: No explicit reused participant cohort or animal dataset was identified in the reviewed comparisons. This does not establish independence of every laboratory dataset.

Last reviewed

24 November 2026

Help the next reader

Help people check the facts before they buy.

Hydrogenology keeps 761 source-checked records accessible without advertising or product promotion.

Support independent access
Help us correct the recordReport a discrepancy

Send the exact difference between this page and the linked source. The study reference is attached automatically.