Nanocatalytic anti-inflammatory therapy for alleviating rheumatoid lesions with endothelial cell-derived hydrosilicene.
Dong J, Yu W, Huang M, Li Z, Lu Y, Chen J, Chen Z, Zhang X. · Journal of Nanobiotechnology. 2026;24:1055.
Study at a glance
Researchers tested hydrogen-releasing silicon nanosheets coated with endothelial-cell membranes in laboratory assays and mice with experimentally induced arthritis. The coating helped the material attach to activated neutrophils, and treated mice showed less joint inflammation and better bone/cartilage measurements than untreated arthritic controls. Human neutrophils came from one healthy donor; no patients received the treatment. The experiments were small, the treatment-start descriptions conflict, and the effects of hydrogen cannot be fully separated from the silicon material and its membrane coating. These findings do not show that inhaled hydrogen or hydrogen water treats rheumatoid arthritis.
Preclinical
Endothelial-cell cultures, neutrophils from one healthy donor and male DBA/1 mice with collagen-induced arthritis; no treated patients.
HUVEC-membrane-coated hydrosilicene nanosheets (HSI@ECM), hydrogen-generating silicon-based material, approximately 300 nm lateral size and <15 nm thickness. Neutrophil exposure commonly 100 micrograms material/mL. Arthritis treatment: 100 micrograms material/mL, 10 microlitres/paw by hind-footpad injection every other day (1 microgram material/paw); this is material mass, not an administered H2 gas dose. Collagen 100 micrograms plus CFA at primary immunization, IFA booster day 21. · HUVEC-membrane-coated hydrosilicene nanosheets (HSI@ECM), hydrogen-generating silicon-based material, approximately 300 nm lateral size and <15 nm thickness. Neutrophil exposure commonly 100 micrograms material/mL. Arthritis treatment: 100 micrograms material/mL, 10 microlitres/paw by hind-footpad injection every other day (1 microgram material/paw); this is material mass, not an administered H2 gas dose. Collagen 100 micrograms plus CFA at primary immunization, IFA booster day 21.
Arthritis evaluation at 6 and 9 weeks; injection start is inconsistent: methods describe assignment at day 28, whereas results describe treatment from primary immunization. Cell toxicity evaluated at 24/48/72 h.
The coated material showed stronger adhesion to activated neutrophils than uncoated/red-cell-coated controls and reduced pathological ROS and NET-related signals in experimental assays. Basal neutrophil ROS was not significantly altered in the supplementary comparisons. In arthritic mice the authors reported lower arthritis scores, paw swelling and temperature and better bone/cartilage measures with HSI@ECM than disease controls; figures generally favour the coated material over uncoated HSI. Numerical whole-animal effect sizes were not extracted from graph pixels. HUVEC viability was not significantly reduced in the short culture assays at the investigated concentrations up to 200 micrograms/mL. This is a limited cell screen, not comprehensive systemic safety testing.
Single healthy-donor neutrophils do not establish effects in rheumatoid-arthritis patients; n=3 measurements must not be presented as three human participants.
What kind of evidence is this?
Preclinical
Cell/material experiments, ex vivo healthy-donor neutrophils and collagen-induced arthritis in male DBA/1 mice; not a human treatment study.
Musculoskeletal and pain research
Other forms
Preclinical findings with attribution limits
Arthritis index, paw swelling/temperature, micro-CT bone microstructure, cartilage histology/Mankin score, ROS, NET markers MPO/NE/CitH3/PAD4, mitochondrial membrane-potential assays and material biocompatibility.
Methods
Endothelial-cell cultures, neutrophils from one healthy donor and male DBA/1 mice with collagen-induced arthritis; no treated patients.
Neutrophils from one healthy human donor; HUVEC culture assays. Male DBA/1 mice aged 6–8 weeks; figure captions specify n=4/group for arthritis/histological endpoints, with n=3 for several cell assays. Total unique mice across 6- and 9-week endpoints is not transparently mapped.
Arthritis evaluation at 6 and 9 weeks; injection start is inconsistent: methods describe assignment at day 28, whereas results describe treatment from primary immunization. Cell toxicity evaluated at 24/48/72 h.
HUVEC-membrane-coated hydrosilicene nanosheets (HSI@ECM), hydrogen-generating silicon-based material, approximately 300 nm lateral size and <15 nm thickness. Neutrophil exposure commonly 100 micrograms material/mL. Arthritis treatment: 100 micrograms material/mL, 10 microlitres/paw by hind-footpad injection every other day (1 microgram material/paw); this is material mass, not an administered H2 gas dose. Collagen 100 micrograms plus CFA at primary immunization, IFA booster day 21.
Hydrogen-generating silicon nanosheets delivered by local footpad injection.
HUVEC-membrane-coated hydrosilicene nanosheets (HSI@ECM), hydrogen-generating silicon-based material, approximately 300 nm lateral size and <15 nm thickness. Neutrophil exposure commonly 100 micrograms material/mL. Arthritis treatment: 100 micrograms material/mL, 10 microlitres/paw by hind-footpad injection every other day (1 microgram material/paw); this is material mass, not an administered H2 gas dose. Collagen 100 micrograms plus CFA at primary immunization, IFA booster day 21.
Healthy control; arthritis plus PBS; uncoated HSI; membrane-coated HSI; methotrexate 5 mg/kg. Cell work includes PMA-stimulated controls, NAC 10 mM, and red-cell-membrane-coated material in adhesion experiments.
Outcomes and reported result
Arthritis index, paw swelling/temperature, micro-CT bone microstructure, cartilage histology/Mankin score, ROS, NET markers MPO/NE/CitH3/PAD4, mitochondrial membrane-potential assays and material biocompatibility.
The coated material showed stronger adhesion to activated neutrophils than uncoated/red-cell-coated controls and reduced pathological ROS and NET-related signals in experimental assays. Basal neutrophil ROS was not significantly altered in the supplementary comparisons. In arthritic mice the authors reported lower arthritis scores, paw swelling and temperature and better bone/cartilage measures with HSI@ECM than disease controls; figures generally favour the coated material over uncoated HSI. Numerical whole-animal effect sizes were not extracted from graph pixels. HUVEC viability was not significantly reduced in the short culture assays at the investigated concentrations up to 200 micrograms/mL. This is a limited cell screen, not comprehensive systemic safety testing.
Published complete main text and supplementary DOCX reviewed. Complete supplementary DOCX text/captions S1–S10 reviewed and embedded raster images inspected; vector panels were not independently digitized. Null findings, source inconsistencies and unreported values are retained; no independent reanalysis.
No significant short-term endothelial-cell cytotoxicity reported; comprehensive animal adverse-event surveillance, chronic clearance and toxicity were not established.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Single healthy-donor neutrophils do not establish effects in rheumatoid-arthritis patients; n=3 measurements must not be presented as three human participants. Small animal endpoint groups; no prospective power calculation or clear blinded outcome assessment identified. Total unique animal allocation and treatment timing are incompletely reconciled. Composite H2-generating silicon/membrane intervention: material targeting, silicon chemistry and H2 effects are not fully separated by a matched gas-only comparator. Actual in vivo H2 exposure is not established by material concentration. PMA activation is an artificial neutrophil model; proposed ROS/NET causal mechanisms remain preliminary. No clinical efficacy, inhaler/water efficacy or long-term systemic safety conclusion is justified.
The reported population or experimental model and protocol only; clinical benefit and general safety are not established.
National Natural Science Foundation of China 82302777.
Authors declare no competing interests.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
PMID: 43009968 · DOI: 10.1186/s12951-026-04930-0
Published main full text available through the linked original source.
No correction, retraction or expression-of-concern notice identified in supplied full text/metadata or targeted DOI searches on 24 November 2026. Limited notice screen, not an integrity certification.
Editorial integration of the supplied source review; not independent medical or statistical validation.
Complete published main XML read through disclosures. Supplementary DOCX text/captions S1–S10 read; embedded raster images inspected. Vector-only panels were not independently digitized; no numerical effects inferred from unreadable images. Supplementary scope: Complete supplementary DOCX text/captions S1–S10 reviewed and embedded raster images inspected; vector panels were not independently digitized.
Complete published main full-text article reviewed using the supplied study-specific review packet. Supplementary scope is stated separately; no independent clinical, statistical or image-forensic validation.
Ethics and consent reporting: Shanghai General Hospital human ethics 2024KS439 (one healthy donor); animal approval 2024SC030. Related-data limitations: No explicit reused participant cohort or animal dataset was identified in the reviewed comparisons. This does not establish independence of every laboratory dataset.
24 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 761 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy