The first experience of the combined use of nitric oxide and molecular hydrogen for cardiac surgery in high-risk patients
Pichugin VV, Deryugina AV, Domnin SE, Shirshin AS, Fedorov SA, Buranov SN, Zhurko SA, Ryazanov MV, Brychkin YuD, Danilova DA. · Pulmonologiya. 2024;34(1):32–41.
Study at a glance
This small cardiac-surgery study compared standard bypass care, nitric oxide, and nitric oxide plus hydrogen in 91 patients. The combined group had lower postoperative heart-injury markers and shorter ventilation and intensive-care times than the nitric-oxide group. There were no deaths in any group, and a shorter total hospital stay was not established. The gases entered the heart–lung machine, not an ordinary nasal cannula. The study does not show what hydrogen alone would do. Inconsistencies in group labels and the reported hydrogen concentration, limited follow-up and unresolved independence from related reports reduce confidence.
Read the related patient report →Read the related patient report →
Human
91 adults undergoing high-risk valve or combined valve/coronary surgery.
NO 40 ppm plus H₂ reported as 1.2 ppm, supplied to the gas line of the extracorporeal bypass oxygenator, from target perfusion until approximately five minutes before bypass ended. The paper repeatedly prints 1.2 ppm in Russian and English; do not silently convert to 1.2%, 1.2 L/min, or a nasal-cannula dose. Device: BozonH2/O3 UVcontrol; NO generator Tianox. · NO 40 ppm plus H₂ repeatedly printed as 1.2 ppm. The unit remains unresolved and must not be changed to 1.2%, 1.2 L/min or a home-inhaler dose. Actual blood/oxygenator hydrogen exposure was not measured.
Intraoperative administration; troponin/echocardiographic outcomes through 48 h and inpatient outcomes. Mean bypass time in combined arm 117.4 ± 45.1 minutes.
At 12 h, troponin I was 1.20 ± 0.15 ng/mL with NO+H₂, 1.89 ± 0.30 with NO and 3.41 ± 0.40 with standard bypass; at 48 h, 0.70 ± 0.07, 1.40 ± 0.15 and 1.65 ± 0.15 respectively. Authors mark combined treatment significantly lower than both comparators at 12, 24 and 48 h; immediate postoperative NO+H₂ versus NO difference was not significant. Ventilation time was 4.7 ± 0.5 h with NO+H₂ versus 6.9 ± 0.7 with NO and 8.0 ± 0.5 with standard care; ICU time 27.1 ± 1.5 versus 33.2 ± 1.1 versus 40.0 ± 2.3 h. Table 5 marks combined versus NO differences significant. Acute heart failure occurred in 4/30 standard-care patients and 0 in each active group; authors report P=0.046 versus standard care. Respiratory/multiple-organ failure differences were not significant; deaths were zero in all three arms. Hospital stay 9.5 ± 2.0, 10.1 ± 2.1 and 11.0 ± 2.7 days was not marked significant.
Small single-centre study, no H₂-only arm; the strongest hydrogen-specific comparison is adding H₂ to NO, not proving benefit of H₂ alone.
What kind of evidence is this?
Human
Single-centre pilot study with envelope randomization into standard cardiopulmonary bypass, nitric oxide (NO), and NO plus molecular hydrogen. Adults with NYHA III–IV symptoms undergoing valve or combined valve/coronary surgery. No H₂-only arm; no blinding, trial registration or prospective sample-size calculation reported.
Cardiovascular and circulatory health
Other forms
Uncontrolled clinical observations
Troponin I, myocardial-injury index, echocardiographic function, mechanical-ventilation duration, acute heart/respiratory/multiple-organ failure, ICU and hospital stay, inpatient mortality.
Methods
91 adults undergoing high-risk valve or combined valve/coronary surgery.
91 patients: standard bypass n=30, NO n=33, NO plus H₂ n=28 according to Russian methods and tables. The English abstract reverses the two active-arm sample sizes; use the main methods/table values and retain the discrepancy.
Intraoperative administration; troponin/echocardiographic outcomes through 48 h and inpatient outcomes. Mean bypass time in combined arm 117.4 ± 45.1 minutes.
NO 40 ppm plus H₂ reported as 1.2 ppm, supplied to the gas line of the extracorporeal bypass oxygenator, from target perfusion until approximately five minutes before bypass ended. The paper repeatedly prints 1.2 ppm in Russian and English; do not silently convert to 1.2%, 1.2 L/min, or a nasal-cannula dose. Device: BozonH2/O3 UVcontrol; NO generator Tianox.
Nitric oxide plus hydrogen supplied to the extracorporeal bypass oxygenator gas line, not a nasal cannula.
NO 40 ppm plus H₂ repeatedly printed as 1.2 ppm. The unit remains unresolved and must not be changed to 1.2%, 1.2 L/min or a home-inhaler dose. Actual blood/oxygenator hydrogen exposure was not measured.
Standard oxygen/air bypass (n=30) and NO 40 ppm alone (n=33), with shared cold crystalloid cardioplegia and surgical care.
Outcomes and reported result
Troponin I, myocardial-injury index, echocardiographic function, mechanical-ventilation duration, acute heart/respiratory/multiple-organ failure, ICU and hospital stay, inpatient mortality.
At 12 h, troponin I was 1.20 ± 0.15 ng/mL with NO+H₂, 1.89 ± 0.30 with NO and 3.41 ± 0.40 with standard bypass; at 48 h, 0.70 ± 0.07, 1.40 ± 0.15 and 1.65 ± 0.15 respectively. Authors mark combined treatment significantly lower than both comparators at 12, 24 and 48 h; immediate postoperative NO+H₂ versus NO difference was not significant. Ventilation time was 4.7 ± 0.5 h with NO+H₂ versus 6.9 ± 0.7 with NO and 8.0 ± 0.5 with standard care; ICU time 27.1 ± 1.5 versus 33.2 ± 1.1 versus 40.0 ± 2.3 h. Table 5 marks combined versus NO differences significant. Acute heart failure occurred in 4/30 standard-care patients and 0 in each active group; authors report P=0.046 versus standard care. Respiratory/multiple-organ failure differences were not significant; deaths were zero in all three arms. Hospital stay 9.5 ± 2.0, 10.1 ± 2.1 and 11.0 ± 2.7 days was not marked significant.
Published main full text reviewed. Source inconsistencies, null results and unreported values are retained; no independent reanalysis.
Source reports no early complications in active groups and no deaths in any arm; control had acute heart failure 4/30, respiratory failure 3/30 and multiple-organ failure 2/30. This is limited early follow-up, not comprehensive device safety.
A reported association, difference or mechanism is not automatically a clinical benefit.
Limitations and applicability
Small single-centre study, no H₂-only arm; the strongest hydrogen-specific comparison is adding H₂ to NO, not proving benefit of H₂ alone. Source inconsistencies: English abstract active-arm n is reversed; prose says ejection fraction higher in control whereas table 4 shows higher active-arm values; methods list fewer troponin timepoints than results. Do not smooth these conflicts away. H₂ concentration is printed as 1.2 ppm but cannot be independently resolved from the source. Actual achieved blood or oxygenator H₂ exposure was not reported. Several surrogate endpoints/multiple comparisons and short follow-up; no mortality difference or long-term clinical benefit established. Safety experience in a small monitored surgical sample is not evidence about home inhalators.
The population or experimental model and protocol described here; clinical benefit and general safety are not established.
Authors state the study was not sponsored.
Authors declare no conflicts of interest.
No single-study GRADE certainty rating is assigned. Read how records and evidence assessments are prepared.
Sources and record status
Source ID: doi-10.18093-0869-0189-2024-34-1-32-41 · DOI: 10.18093/0869-0189-2024-34-1-32-41
Published main full text available through the linked original source.
Source verification based on the supplied publication review. This is editorial extraction, not independent medical or statistical validation.
Complete original-language published PDF, including methods, results, tables, figure captions, discussion, references and disclosures read. Key data pages visually inspected. No independent statistical reanalysis. No separate supplementary files identified.
Complete published main full-text article reviewed. Supplementary review scope is stated separately; no independent medical, statistical or image-forensic validation.
22 November 2026
Help people check the facts before they buy.
Hydrogenology keeps 740 source-checked records accessible without advertising or product promotion.
Help us correct the recordReport a discrepancy
Send the exact difference between this page and the linked source. The study reference is attached automatically.